My WebLink
|
Help
|
About
|
Sign Out
PC-92-13
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1992
>
PC-92-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:49 AM
Creation date
4/20/2005 2:53:44 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
2/12/1992
DOCUMENT NO
PC-92-13
DOCUMENT NAME
PUD-91-10
NOTES
RED BEAR, INC.
NOTES 3
22-UNIT SENIOR APT.
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />37. <br /> <br />38. <br /> <br />39. <br /> <br />40. <br /> <br />41. <br /> <br />42. <br /> <br />43. <br /> <br />T~at all eXisting wells, se~tic tanks or holding tanks on the <br />SIte be properly sealed, fIlled and abandoned prior to the <br />start of grading operations unless Zone 7 retains specific <br />wells tor observation wells, or special approval is obtained <br />from the City Engineer for temporary use of an existing well <br />for construction water. Any wells designated for abandonment <br />or any wells, encountered during construction, are to be <br />destroyed in accordance with a permit obtained from Zone 7 by <br />calling (415) 443-9300. <br /> <br />That the haul route for all materials to and from this <br />development be approved by the City Engineer prior to the <br />start of any construction. <br /> <br />That the developer submit an erosion and sedimentation control <br />plan or procedure as part of the improvement plans prior to <br />the final approval of the development. <br /> <br />That the developer submit a dust control plan or procedure as <br />part of the improvement plans prior to the final approval of <br />the development. <br /> <br />That storm drainage swales, gutters, inlets, outfalls, and <br />channels not within the area of a dedicated public street or <br />public service easement approved by the City Engineer be <br />privately maintained by the property owners or through an <br />association approved by the City. <br /> <br />That approval of the water supply and distribution system be <br />withheld pendinq final design and until the developer has <br />demonstrated to the satisfaction of the City Enqineer that the <br />proposed syste. meets both the immediate and long-range <br />requirements for supplying water in this area. <br /> <br />That the developer comply with any and all applicable <br />require.ents of the cross-connections control and backflow <br />prevention device proqrams required by the California <br />Administrative Code, Title 17. <br /> <br />44. That approval for the nUlllber, type and location of fire <br />hydrants be withheld pendinq final desiqn, review by the Fire <br />Marshal, and final review by the City Enqineer. <br /> <br />45. That approval of the sanitary sewer syst_ be withheld pending <br />final desiqn and until the developer has d_onstrated to the <br />satisfaction of the City Enqineer that the proposed system is <br />adequate, connects to an approved point of discharqe, and <br />meets both the i..ediate and lonq-ranqe require.ents of the <br />sanitary syst.. in this and all tributary areas. <br /> <br />Rev. 2/84 10/84 5/86 10/86 <br />
The URL can be used to link to this page
Your browser does not support the video tag.