My WebLink
|
Help
|
About
|
Sign Out
PC-96-99
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1996
>
PC-96-99
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:18 AM
Creation date
3/2/2005 4:14:54 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
12/11/1996
DOCUMENT NO
PC-96-99
DOCUMENT NAME
TM 6902
NOTES
PATCO INT'L INC.
NOTES 3
SUBDIVIDE INTO 11 RES. LOTS/1 COMMON AREA
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Resolution No. PC-96-99 <br />Page 5 <br /> <br />9. The proposed six inch (6") sanitary sewer main shall be connected to the existing sewer <br />main located in Del V aile Parkway with a manhole. The existing eight inch (8") sewer <br />main in Del Valle Parkway east of the manhole shall be plugged and the existing main <br />shall be abandoned per City Standards. The design(s) for this work shall be shown on the <br />improvement plans for review and approval by the City Engineer prior to recordation of <br />the final map. <br /> <br />10. The proposed storm drain connection to the existing thirty inch (30") storm drain line <br />shall be relocated to the top of bank. A twelve foot (12' 0") wide all-weather access shall <br />be provided to this manhole connection. The design(s) for this work shall be shown on <br />the improvement plan for review and approval by the City Engineer prior to recordation <br />of the final map. <br /> <br />11. A special foundation system shall be used for the unit located on Lot No. 11 that will <br />support this unit if the arroyo bank should fail. The design of this foundation system <br />shall be submitted to the building official for review and approval prior to issuance ofthe <br />building permits for this unit. <br /> <br />12. No fencing shall be allowed within the public service easement adjacent to the private <br />streets. A fencing plan shall be provided to the Planning Director for review and <br />approval prior to recordation ofthe final map. <br /> <br />13. All work to be done within the Arroyo Del Valle requires an encroachment permit issued <br />by the Alameda Water Quality and Flood Control District Zone 7 and a streambed <br />alteration permit issued by the California State Department ofFish and Game. Said <br />permits shall be secured before project construction begins. <br /> <br />{end} <br />
The URL can be used to link to this page
Your browser does not support the video tag.