My WebLink
|
Help
|
About
|
Sign Out
PC-96-64
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1996
>
PC-96-64
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:15 AM
Creation date
12/30/2004 1:39:32 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
8/24/1996
DOCUMENT NO
PC-96-64
DOCUMENT NAME
PUD-96-13
NOTES
DELTA PROPERTIES
NOTES 3
RETAIL CENTER, CANDLEWOOD HOTEL, IN-N-OUT BURGER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Resolution No. PC-96-64 <br />Page 15 <br /> <br />Gradin~ and Draina~e <br /> <br />57. The developer shall submit a final grading and drainage plan prepared by a licensed civil <br />engineer depicting all final grades and on-site drainage control measures, including <br />concrete-lined V -ditches, to protect all cut and fill slopes from surface water overflow. <br />This plan shall be subject to the review and approval of the City Engineer and/or the <br />Director of Building Inspection prior to the issuance of any building permits. <br /> <br />58. The developer shall submit an erosion and sedimentation control plan or procedure as part <br />of the improvement plans. Grading completed prior to October 15 shall be revegetated and <br />stabilized by October 15. Grading completed between October 16 and April 15 shall be <br />revegetated and restabilized as soon as possible after completion of grading. <br /> <br />59. The developer shall submit a refundable cash bond for hazard and erosion control prior to <br />issuance of an Engineering or Building Department permit. The amount of this bond will <br />be determined by the City Engineer. <br /> <br />60. The developer shall submit a dust control plan or procedure as part of the improvement <br />plans. <br /> <br />61. Approval of the storm drainage system shall be subject to the review and approval of the <br />City Engineer and Zone 7, as applicable, that the system is adequate, connects to an <br />approved point of discharge, meets any and all applicable requirements of the Alameda <br />County Flood Control District - Zone 7, meets any and all applicable requirements of the <br />Federal Emergency Management Flood Hazard Program, the California Department ofFish <br />and Game, and meets the immediate and long-range requirements of this development and <br />all upstream areas intended to be drained through this development. <br /> <br />Utilities. Li~htin~. Landsc&pin~ <br /> <br />62. All utilities required to serve any existing or proposed development on-site shall be <br />installed underground, unless otherwise determined by the City Engineer. <br /> <br />63. Electric power distribution, gas distribution, communication service, Cable television, and <br />any required alarm systems shall be installed underground in a joint utility trench unless <br />otherwise specifically approved by the City Engineer or Director of Building Inspection for <br />on-site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.