My WebLink
|
Help
|
About
|
Sign Out
PC-2025-21
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2025
>
PC-2025-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2025 10:35:23 AM
Creation date
12/23/2025 10:35:19 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
10/22/2025
DESTRUCT DATE
PERMANENT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PUD-54-01M Planning Commission <br />Page 4 of 6 <br /> <br /> <br />18. HIGH VISIBILITY SAFETY APPAREL: All workers on foot who are exposed to the hazard of <br />vehicular traffic shall wear warning garments such as vests, jackets, or shirts manufactured in <br />accordance with the requirements of the American National Standards Institute <br />(ANSI)/International Safety Equipment Association (ISEA) 107-2004 Performance Class 2, high <br />visibility safety apparel and headwear, or any updates adopted by Cal OSHA. During hours of <br />darkness, warning garments shall be retroreflective with visibility from a minimum 1,000 feet. <br />(Address this condition during construction) <br /> <br />19. EXCAVATION SAFETY: All excavations must be performed in conformance with California <br />Government Code Section 4216 et seq. No excavation shall occur until proper notice is <br />provided to Underground Service Alert (usanorth811.org) by calling either 811 or 800-642-2444 <br />at least 72-hours prior to the work so buried utilities can be marked. All excavations shall be <br />covered or barricaded to prevent entry when work is inactive. Open excavations in the public <br />right-of-way must be covered by skid-resistant steel plates that are firmly affixed to the surface <br />with leading edges ramped. Excavations 5 feet and deeper require a protective system as <br />defined by Cal-OSHA. If a shoring system or trench boxes will be utilized as the protective <br />system, said system shall either be manufactured and installed according to manufacturer <br />recommendations, or designed by a registered professional engineer and installed according to <br />approved plans. No excavation shall be performed atop or adjacent to a high -risk facility until <br />authorized by the owner of the facility. High-risk facilities are defined as gas transmission <br />pipelines and hazardous liquid pipelines as regulated by the U.S. Department of Transportation <br />Pipeline and Hazardous Materials Safety Administration (US DOT PHMSA) (Address this <br />condition during construction) <br /> <br />20. POLLUTANT REDUCTION IN STORMWATER: At no time during construction of the project <br />shall pollutants be allowed to enter, clog, or contaminate storm drain pipe networks or open <br />stormwater channels in violation of Pleasanton Municipal Code §9.14.080 et seq. The <br />applicant shall contain all trash and debris for proper disposal to authorized landfills or <br />recyclers. Erosion control features shall be deployed during the rainy season that extends <br />from October 1 to April 15 each year, or any time rain is forecast outside of this period. Best <br />Management Practices (BMPs) shall be strictly followed. Street sweepers must be employed <br />if soil or debris is tracked onto the public roads from vehicles exiting the site. Standard <br />BMPs are available from the California Stormwater Quality Association (CASQA), the United <br />States Environmental Protection Agency (EPA), Caltrans, and others. Notes and/or <br />illustrations shall be added to the plans that describe the BMPs to be utilized during <br />construction. The use of manufactured erosion control woven blankets and straw wattles that <br />utilize plastic monofilament netting is specifically prohibited. (Address this condition during <br />construction) <br />21. DUST CONTROL: Dust control measures must be employed during all phases of <br />construction to prevent airborne nuisance to neighboring properties. All stockpiles or unused <br />materials that can create dust shall be covered or removed. Exposed soil areas shall be <br />routinely watered until surfacing materials or landscaping is installed. Use of dust palliatives <br />shall conform to Caltrans Standard Specification Section 18. Any damage caused by <br />airborne dust to neighboring properties shall be cleaned with costs paid by the applicant. If <br />the applicant fails the address dust as directed by the City, the City shall have the right to <br />enter the property to effectuate the correction, with all costs paid by the applicant or levied as <br />a lien against the applicant’s property. (Address this condition during construction) <br /> <br />22. PROPERTY NUISANCE: At no time during construction of the project shall the condition of <br />the property become a nuisance as defined in Pleasanton Municipal Code §9.28.020. The <br />Docusign Envelope ID: 63163211-FC8F-4F3F-A005-3BD4A6E50863
The URL can be used to link to this page
Your browser does not support the video tag.