My WebLink
|
Help
|
About
|
Sign Out
PC-97-65
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1997
>
PC-97-65
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:08 AM
Creation date
12/29/2004 11:06:26 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
8/13/1997
DOCUMENT NO
PC-97-65
DOCUMENT NAME
PUD-81-30-71D
NOTES
SECURITY CAPITAL PACIFIC TRUST/PRUDENTIAL INSURANCE
NOTES 3
540-UNIT APARTMENT COMPLEX
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Resolution No. PC-97-65 <br />Page 15 <br /> <br />65. The traffic signal at the intersection of Rosewood Drive/Owens Drive shall be modified <br />to provide controls for the new fourth "leg" of the intersection created by the main <br />driveway entrance to the project. The developer shall design and install all necessary <br />signing, striping, signal heads, and signalization loops in accordance with City of <br />Pleasanton standards and to the satisfaction of the City Engineer. The off-site <br />improvement plans shall be subject to the review and approval of the City Engineer prior <br />to the issuance of building permits. The applicant shall be responsible for a pro-rata share <br />as determined by the City Engineer for the maintenance ofthe traffic signaL <br /> <br />66. Top-of-curb grades shall be equal to or higher than the current FEMA 100-year flood <br />elevation. <br /> <br />67. If more than 20 units are to be constructed in anyone phase of construction, two access <br />points to the construction area shall be provided for each phase to the satisfaction of the <br />City Engineer and Fire Marshall. <br /> <br />68. The storm drainage from each building shall be directed to the street or an approved <br />storm drain system in accordance with Sections 2907(b)(5) and 7012(d) of the 1988 <br />Uniform Building Code unless otherwise approved by the Building Official and City <br />Engineer. <br /> <br />69. The applicant shall post with the City prior to a building permit a performance bond for <br />all public improvements that are to be accepted by the City. <br /> <br />70. Other than the proposed driveways, no additional access driveways from Lot 60 shall be <br />permitted onto Owens or Hacienda Drives. The final map or parcel map shall indicate <br />this restriction. <br /> <br />71. All drive aisles shall be signed for no parking except in designated parking areas. <br /> <br />72. The applicant shall submit a final grading and drainage plan prepared by a licensed civil <br />engineer depicting all final grades and on-site drainage control measures. This plan shall <br />be subject to the review and approval of the City Engineer and!or the Director of Building <br />Inspection prior to the issuance of any building permits. <br /> <br />73. The applicant shall submit a refundable cash bond for hazard and erosion control prior to <br />issuance of an Engineering or Building Department permit. The amount of this bond will <br />be determined by the City Engineer. <br /> <br />74. All existing wells on the site shall be removed or sealed, filled and abandoned pursuant to <br />Alameda County Ord. 73-68, prior to the start of grading operations unless Zone 7 retains <br />specific wells for observation wells, or special approval is obtained from the City <br />Engineer for temporary use of an existing well for construction water. Any wells <br />designated for abandonment or any wells, encountered during construction, are to be <br />destroyed in accordance with a permit obtained from Zone 7. <br />
The URL can be used to link to this page
Your browser does not support the video tag.