Laserfiche WebLink
• Above Elevation 540: Homes situated above the normal upper limit of the <br />Bonde Zone will need to take special measures to provide adequate water <br />pressure for both domestic and fue fighting needs. To ensure a minimum <br />of 40 psi for domestic needs, a small hydro-pneumatic booster pump <br />system will be required to serve each residence. The pump systems are <br />to be privately owned and maintained . Another special facility required <br />for fue protection will include fire sprinkler systems with control devices <br />to assure adequate storage and pressure. Compliance with fue safety <br />standards will need to be verified by the Fire Marshall prior to the <br />issuance of any new building permits on properties occupied with <br />residences located above elevation 540. <br />b. Distribution <br />The recently completed Zone 7 trunk line will be the primary source for <br />providing water to properties within the Plan Area. This treated water source <br />will be accessed through improvements to the existing Zone 7 Turnout #6 , located <br />next to the fue station adjacent to the easterly border of the Plan Area <br />(Figure VI-1). Currently functioning as part of a looped supply to the Ruby Hill <br />pump station, this turnout will be appropriately valved and improved to <br />concurrently supply a new Bonde Zone pump station for the Plan Area . The new <br />pump station will be located adjoining the turnout and fire station, and will feed <br />a 16-inch Bonde Zone trunk line running westerly within the Vineyard Avenue <br />right-of-way. <br />The new Vineyard A venue trunk line will extend westerly to connect with the <br />existing 16-inch Bonde Zone line in the vicinity of Lot 15. Valving will be <br />needed at both ends of the system in order to balance the hydraulic pressures and <br />flows . These connections will serve to loop both systems , thereby enhancing the <br />reliability and capacity of each. Secondary distribution lines will extend short <br />distances to the south and north from the main trunk line in order to provide <br />service to all Plan Area properties. In addition, a secondary water line loop <br />connection will be constructed as an independent City project to connect Vineyard <br />Avenue at Lot 14 with Foxbrough Place. <br />c. Storage <br />Additional water storage to provide adequate domestic service and sustained fue <br />flow capability will be provided by building a new storage tank at elevation 636 <br />on Lot 25. The tank will be sited within the saddle of a ridgeline in the southern <br />portion of the Plan Area as shown in Figure VI-1 . This tank will be of sufficient <br />size to serve local Plan Area properties while also enhancing the reliability of the <br />existing Bonde Zone system. <br />77