Laserfiche WebLink
<br /> <br /> <br /> <br />P22-1089, PUD-147, Tract 8522 PC-2024-14, June 26, 2024 <br /> <br />21 <br /> <br />B. Project-Specific Implementation Measures for Compliance with MM NOI-1: <br />• To the maximum extent practical, the following measures should be incorporated <br />into the project construction operations: <br />o Noise-generating construction activities shall not occur within the hours <br />identified in Noise Ordinance Section 9.04.100. <br />o Locate stationary construction equipment as far from adjacent occupied <br />buildings as possible. <br />o All noise-producing project equipment and vehicles using internal-combustion <br />engines shall be equipped with manufacturers-recommended mufflers and be <br />maintained in good working condition. <br />o All mobile or fixed noise-producing equipment used on the project site that are <br />regulated for noise output by a federal, state, or local agency shall comply with <br />such regulations while in the course of project activity. <br />o All construction equipment must meet California Department of Motor Vehicles <br />(DMV0) noise standards and shall be equipped with muffling devices. <br />o Electrically powered equipment shall be used instead of pneumatic or internal- <br />combustion-powered equipment, where feasible. <br />o Material stockpiles and mobile equipment staging, parking, and maintenance <br />areas shall be located as far as practicable from noise-sensitive receptors. <br />o Select routes for movement of construction-related vehicles and equipment so <br />that noise-sensitive areas, including residences, and outdoor recreation areas, <br />are avoided as much as possible <br />o Project area and site access road speed limits shall be established and <br />enforced during the construction period. <br />o Nearby residences shall be notified of construction schedules so that <br />arrangements can be made, if desired, to limit their exposure to short-term <br />increases in ambient noise levels. <br />o Designate a noise disturbance coordinator who will be responsible for <br />responding to complaints about construction noise. The telephone number of <br />the noise during disturbance coordinator shall be conspicuously posted at the <br />construction site and shall be provided to the City of Pleasanton. Copies of the <br />construction schedule <br /> <br />• The following measures should be incorporated into the building facade <br />construction: <br />o For the seven (7) lots located nearest to Interstate 680, the north-, east-, and <br />south-facing upper-floor building facades should maintain minimum window <br />assembly STC ratings of 32. Figure 2 [in the Noise and Vibration Assessment <br />prepared by Bollard Acoustical Consultants, Inc., dated “Received” on <br />December 27, 2022], illustrates the facades requiring improved STC rated <br />windows. <br />o Standard residential construction practices (wood or stucco siding, STC-27 <br />windows, door weather-stripping, exterior wall insulation, composition plywood <br />roof) would be adequate for the remainder of the development. <br />o Mechanical ventilation (air conditioning) should be provided for all residences in