20.10.060 <br /> 787 (Pleasanton Supp. No. 29, 1-23) <br />2. Fire sprinklers shall be provided in garages. <br />Fire sprinklers shall be intermediate rated, <br />quick response type, with a maximum cov- <br />erage area of 130 square feet per sprinkler. <br /> <br />R313.2 Large One- and Two-Family Dwelling <br />Residential Sprinkler Systems. In addition to the <br />requirements specified in R313.1, one- and two- <br />family dwellings with a habitable floor area <br />greater than 7,500 square feet shall have an auto- <br />matic fire-sprinkler system designed to include all <br />sprinklers within a compartment, up to a maxi- <br />mum of four sprinklers. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019; Ord. 2153 § <br />2, 2016) <br /> <br />20.10.060 CRC Table R602.10.3(3) amended— <br />Bracing requirements based on seismic <br />design category. <br /> Table R602.10.3(3) is amended to read as follows: <br /> <br />Table column title MINIMUM TOTAL LENGTH <br />(FEET) OF BRACED WALL PANELS RE- <br />QUIRED ALONG EACH BRACED WALL <br />LINE is amended to add footnote “i”. <br /> <br /> Footnote “i” is added, to read as follows: <br /> <br />i. Method CS-SFB and Method GB are not <br />permitted, and the use of Method PCP is <br />limited to one-story single-family dwellings <br />and accessory structures. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019; Ord. 2153 § <br />2, 2016) <br /> <br />20.10.070 CRC Section R602.10.4.5 added— <br />Limits on methods GB and PCP. <br /> Section R602.10.4.5 is added, to read as follows: <br /> <br />Method GB is not permitted for use as intermittent <br />braced wall panels, but gypsum board is permitted <br />to be placed on the opposite side of the studs from <br />other types of braced wall panel sheathing. The <br />use of Method PCP is limited to one-story single- <br />family dwellings and accessory structures. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019; Ord. 2153 § <br />2, 2016) <br /> <br />20.10.080 CRC Section R902.1 amended— <br />Roofing covering materials. <br /> Section R902.1 is amended to read as follows: <br /> <br />R902.1 Roofing covering materials. Roofs shall <br />be covered with materials as set forth in Sections <br />R904 and R905. A minimum Class B roofing, <br />listed and tested in accordance with UL 790 or <br />ASTM E108, is required in the City of Pleasanton. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019; Ord. 2153 § <br />2, 2016) <br /> <br /> <br />