Laserfiche WebLink
20.08.010 <br /> 783 (Pleasanton Supp. No. 29, 1-23) <br />Chapter 20.08 <br /> <br />PLEASANTON BUILDING CODE* <br /> <br />Sections: <br />20.08.010 California Building Code adopted. <br />20.08.020 CBC Chapter 1 Division I amended. <br />20.08.030 CBC Chapter 1 Division II deleted. <br />20.08.040 CBC Section 903 amended— <br />Automatic sprinkler systems. <br />20.08.050 CBC Section 904 amended— <br />Alternative automatic fire- <br />extinguishing systems. <br />20.08.060 CBC Section 1505.1 amended—Fire <br />classification. <br />20.08.070 CBC Section 1705.3 amended— <br />Concrete construction. <br />20.08.080 CBC Section 1905.1.7 amended— <br />ACI 318 Section 14.1.4. <br /> <br />* Prior ordinance history: Ord. 2083. <br /> <br />20.08.010 California Building Code adopted. <br /> A. The International Building Code, 2021 Edi- <br />tion, as amended and set forth in the California Building <br />Code, Title 24, Part 2 of the California Code of Regula- <br />tions, published by the International Code Council is <br />hereby adopted, together with Appendices C, G, J, and <br />N except as set forth in this chapter. <br /> B. The International Building Code (IBC) <br />adopted in this chapter by reference is amended by the <br />following additions, deletions and amendments thereto <br />as set forth in this chapter. Reference numbers herein are <br />taken from the 2022 California Building Code (CBC). <br /> C. These regulations shall be known as the <br />Pleasanton Building Code, hereinafter referred to as <br />“this code.” <br /> D. Where there is a reference in the code to the <br />“Building Official” or “Authority Having Jurisdiction” it <br />shall mean the “Building and Safety Official” or in the <br />absence of the Building and Safety Official, the interim, <br />temporary or acting Building and Safety Official. (Ord. <br />2241 § 2, 2022; Ord. 2197 § 2, 2019; Ord. 2153 § 2, <br />2016) <br /> <br />20.08.020 CBC Chapter 1 Division I amended. <br /> Chapter 1 Division I Sections 1.8.4, 1.8.5, 1.8.7 <br />and 1.8.8 are deleted. (Ord. 2241 § 2, 2022; Ord. 2197 § <br />2, 2019; Ord. 2153 § 2, 2016) <br /> <br />20.08.030 CBC Chapter 1 Division II deleted. <br /> Chapter 1 Division II is deleted and replaced by <br />Chapter 20.04, the Pleasanton Building Administrative <br />Code. (Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019; Ord. <br />2153 § 2, 2016) <br /> <br />20.08.040 CBC Section 903 amended— <br />Automatic sprinkler systems. <br /> Section 903 of the California Building Code 2022 <br />Edition, (T24 C.C.R. Part 2), and including by reference <br />the International Building Code, 2021 Edition is <br />amended to read as shown in Section 903 of the Pleasan- <br />ton Fire Code (PMC Chapter 20.24). (Ord. 2241 § 2, <br />2022; Ord. 2197 § 2, 2019; Ord. 2153 § 2, 2016) <br /> <br />20.08.050 CBC Section 904 amended— <br />Alternative automatic fire- <br />extinguishing systems. <br /> Section 904 of the California Building Code 2022 <br />Edition, (T24 C.C.R. Part 2), and including by reference <br />the International Building Code, 2021 Edition is <br />amended to read as shown in Section 904 of the Pleasan- <br />ton Fire Code (PMC Chapter 20.24). (Ord. 2241 § 2, <br />2022; Ord. 2197 § 2, 2019; Ord. 2153 § 2, 2016) <br /> <br />20.08.060 CBC Section 1505.1 amended—Fire <br />classification. <br /> Table 1505.1 Minimum Roof Coverings Classifi- <br />cation is deleted, and Section 1505.1 is amended to add <br />the following paragraph to read as follows: <br /> <br />1505.1 General. Roof coverings shall have a <br />Class B or higher fire resistance rating for all <br />buildings regardless of type of construction. <br />(Ord. 2241 § 2, 2022; Ord. 2197 § 2, 2019; Ord. 2153 § <br />2, 2016) <br /> <br />20.08.070 CBC Section 1705.3 amended— <br />Concrete construction. <br /> Section 1705.3 Exception 1 is amended to read as <br />follows: <br /> <br />1705.3 Concrete Construction. Special inspec- <br />tions and tests of concrete construction shall be <br />performed in accordance with this section and Ta- <br />ble 1705.3. <br /> <br />Exception: Special inspections shall not be re- <br />quired for isolated spread concrete footings of <br />buildings three stories or less above grade plane <br />that are fully supported on earth or rock, where the <br />structural design of the footing is based on a speci-