Laserfiche WebLink
facilities . The method and manner for the provision of these funds and/or facilities shall be approved <br />by the PUSD and in place prior to building permit issuance . Written proof of compliance w ith this <br />condition shall be provided by applicant to the City , on a form generated by the PUSD , prior to <br />building permit issuance . <br />ENGINEERING DEPARTMENT -LAND DEVELOPMENT -925-931-5650 <br />Project Specific Conditions of Approval <br />36 . PUBLIC RIGHT-OF-WAY AND EASEMENT DEDICATIONS . <br />a . Parcel Map shall include a 20 '-wide dedication for the Sycamore Road right-of-way dedication <br />to the City . <br />b . Referring to Parcel Map 6416 (Reference B) for the properties to the east, and Parcel Map 5831 <br />(Reference C) for the properties to the west, 8 '-wide public service easements (PSEs) were <br />ded icated across the Sycamore Road frontages . Corresponding 8 '-wide PSEs shall be <br />dedicated across the Sycamore Road frontage of proposed Parcel 1 and Parcel 2 . <br />37 . EXISTING GROUNDWATER WELL: Zone 7 Water Agency is the administering agency for Alameda <br />County 's "Water Wells Ordinance" (General Ordinance No . 0-2015-20). All existing groundwater <br />wells on properties subject to development must be disclosed on plans . Sheet TM-2 states that the <br />existing groundwater well located on Parcel 1 is to be protected . <br />If the well will be used in the future , subm it a "Statement of Future Well Use" form available from <br />Zone 7 Water Agency prior to issuance of a Building Permit. The application form can be found at <br />following website : <br />https ://www .zone ?water. com/sites/ma in/files/file- <br />attachments/statement of future use .pdf?1618854689. <br />If the well is to be decommissioned , the applicant must obtain a well destruction permit from Zone 7 <br />Water Agency prior to issuance of a Building Permit. The application form can be found at following <br />website : <br />https ://www .zone ?water. com/sites/main/files/file-attachments/8-21- <br />20 drilling permit application .pdf?1618854766. <br />38 . PUBLIC STORM DRAINAGE : The unimproved sections of Sycamore Road re ly on a network of <br />roadside ditches for surface dra inage. The applicant 's frontage therefore rece ives drainage from <br />properties to the east which the ditches convey to the west. The design of the applicant's frontage <br />therefore cannot obstruct t his drainage pattern . In addition , ditch drainage should not be directed onto <br />the applicant's private property . <br />To avo id the roadway runoff from entering the property and inundating the bio-retention areas , the <br />proposed 12-inch storm drain pipes located into the public right-of-way on Sycamore Road shall be <br />part of the public network. Grading plans submitted along with the Parcel Map application must show <br />that the proposed storm drain inlets on the property frontage along Sycamore Road shall be <br />positioned to capture runoff at the property corners. Private bioretent ion areas can then connect to <br />this system. <br />PUD-145 Planning Commission <br />Page 6 of 17