Laserfiche WebLink
a. The entry door to the room must be at the end of a hallway or passageway,or open <br /> directly from another room on an accessible route of travel, so that no turn of ninety <br /> (90)degrees or more is necessary to enter the room. <br /> b. The hallway wall opposite the room must be inset enough to allow an area of at least <br /> eight(8) inches deep with at least a sixty(60)inch run centered on the center of the <br /> entry door opening[e.g.,an eight(8)inch by sixty(60)inch notch or alcove.l <br /> c. The hallway wall on the same side as the room must be inset enough to allow an area <br /> of at least eight(8) inches deep with at least a sixty(60)inch run centered on the <br /> center of the entry door opening[e.g.,an eight(8)inch by sixty(60) inch notch or <br /> alcove.} <br /> d. The hallway wall directly opposite the room door must open to another room with at <br /> least a sixty(60)inch opening on a level with the accessible passageway or hallway. <br /> NOTE: Doors or openings to the rooms required to be accessible may be wider and <br /> the notch or alcove smaller if equivalent access is not impeded. In addition,for a <br /> doorway at the end of a hallway,or in other circumstances,the notch or alcove need <br /> not be centered on the doorway if equivalent access is not impeded. <br /> e. Flooring throughout the residential dwelling unit consistent with CBC Chapter 11A. <br /> f. Standards pertaining to residential structures from ANSI A117.1 may be used <br /> throughout this chapter when CBC Chapter 11A does not contain specific standards <br /> or when the ANSI standards are equivalent to the Chapter 11A standards. <br /> 20.75.140 Standards—new construction—permissive options. <br /> A. The developer or builder of a visitable residential dwelling must offer an opportunity to select any <br /> of the features listed in this chapter to an owner or prospective owner of a visitable residential <br /> dwelling at the earliest feasible time after the owner,purchaser, or prospective purchaser is <br /> identified. <br /> B. The developer or builder of a visitable residential dwelling shall construct or install any requested <br /> features identified in this chapter unless it would result in an unreasonable delay in the construction <br /> or significant unreimbursable costs to the developer or builder. <br /> C. The developer or builder of a visitable residential dwelling,at his or her option,may offer or utilize <br /> standards for structural or design features,components or appliances and facilities, including but <br /> not limited to ANSI standards,which meet or exceed Chapter 11A and which offer greater <br /> availability, access or usability,and these are deemed to be in compliance with this chapter. <br /> 20.75.150 Enforcement. <br /> A. It is unlawful for any person or entity to fail to comply with the requirements of this chapter. <br /> Universal Design City Council, September 20 2022 <br /> Exhibit A to Ordinance, PMC Amendments,Page 8 <br />