35. PARALLEL SANITARY SEWER LATERALS. According to Sheet 2 of the PUD plans <br /> (Reference 2), a new lateral is proposed for Parcel 1 immediately adjacent to and parallel <br /> with the existing lateral stub installed with Tract 6596 for Parcel 2. City Standard <br /> Specification Section 11-03A.2 requires free working space along the sides of parallel <br /> pipes of not less than 12" plus the diameter of the pipe. The centerline-to-centerline <br /> separation must therefore be not less than 6" (half pipe) + 12" + 12" + 6" (half pipe) = 36" or <br /> 3' minimum. Since the Parcel 1 lateral will be very close to the common property line <br /> separating Parcel 2 and the neighbor to the north, the design may need to incorporate <br /> some angle fittings to allow the lateral to eventually align with the center of the proposed <br /> 10'-wide private utility easement. Project specific condition. <br /> 36. SUBDIVISION IMPROVEMENT AGREEMENT. As indicated on Sheet 3 of the VTPM <br /> (Reference 3), the Dennis Drive frontage must be fully developed including road widening <br /> and dedication of public right-of-way and easement for public services. Said work shall be <br /> guaranteed by a Subdivision Improvement Agreement drafted by the City Attorney with <br /> sufficient financial security to assure completion of the required work by the subdivider. <br /> Project specific condition. <br /> 37. MONUMENTS. The Parcel Map include two survey monuments (iron pipe with cap) where <br /> the proposed property line between Parcel 1 and Parcel 2 meets the north and south <br /> property lines. In accordance with §66495-66497 of the California Government Code, the <br /> Final Parcel Map must include sufficient durable survey monuments to allow the <br /> subdivision to be retraced. Project specific condition. <br /> 38. UNDERGROUND UTILITIES FOR NEW HOUSE. All new utilities to serve the proposed <br /> house shall be installed underground. Project specific condition. <br /> 39. UTILITY UNDERGROUNDING ON MARTIN AVENUE. The existing overhead joint pole <br /> utilities along the Martin Avenue frontage shall either be placed underground by the <br /> applicant, or the applicant shall deposit funds with the City in an amount proportional to the <br /> applicant's share of the total cost of a future City-sponsored undergrounding project. The <br /> existing joint pole utilities extend on the west side of Martin Avenue from south of Trenery <br /> Drive to the northern cul-de-sac bulb. The applicant's contribution will be $55,560. Project <br /> specific condition. <br /> 40. DESIGN PER CITY STANDARDS: All public improvements shall be designed in <br /> compliance with the City Standard Specifications and Details in effect at the time of the <br /> issuance of the encroachment, grading, or subdivision permit, whichever occurs first. <br /> 41 . CONDITIONS OF APPROVAL: The Conditions of Approval shall be depicted on a plan <br /> sheet(s) in the improvement plans. <br /> 42. GEOTECHNICAL CONSULTANT — DESIGN CERTIFICATION: The applicant shall <br /> comply with the recommendations of the project geotechnical report. The applicant's <br /> California licensed geotechnical engineer shall review and approve all foundation, <br /> retaining walls, drainage and geotechnical aspects of the final grading and improvement <br /> plans and shall certify on the plans or as otherwise acceptable to the Director of <br /> PUD-140 & P21-0079 Planning Commission <br /> Page 7 of 15 <br />oner has determined, in <br /> accordance with any law concerning investigation of the circumstances, the manner and <br /> PUD-140 & P21-0079 Planning Commission <br /> Page 5 of 15 <br />