Laserfiche WebLink
98. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than 300 feet <br />in industrial and commercial developments. Fire hydrants shall be installed at spacing <br />not greater than 400 feet in residential developments. <br />99. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives shall be <br />designated as fire lanes and identified as such by red curb striping and posted with <br />signs at locations approved by the Fire Department. Signs shall be according to State <br />standards and read "No Parking — Fire Lane" and must be shown on the plans. The red <br />curb striping, sign location(s), and sign language shall be included in the building permit <br />submittal for review and approval by the Livermore -Pleasanton Fire Department prior to <br />building permit issuance. <br />a. The following schedule for NO PARKING signs shall apply: <br />Width <br />Requirements <br />36 feet or greater <br />No requirements <br />Between 28 and 36 feet <br />Post one side <br />Between 20 and 28 feet <br />Post both sides <br />Less than 20 feet <br />Not permitted <br />Cul -de -Sac <br />Not permitted <br />100. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 inches <br />unobstructed vertical clearance, 20 feet of unobstructed width (26 feet where occupied <br />building floors exceed 30 feet height), and inside turning radius of 31 feet and outside <br />turning radius of 51 feet. Unobstructed shall mean a clear travel way, excluding parking <br />width, and designed for an emergency vehicle weight of 70,000 pounds under all <br />weather conditions. Unobstructed width shall not include the width of rolled curbs, <br />sidewalks, or non -drivable surfaces. All exterior portions of buildings must be within 200 <br />feet of an access road. Yard and parking area may be able to be located farther than <br />200 feet from access roads, depending on the specific use. <br />101. FIRE VEHICLE TURNAROUNDS: Where Fire Department vehicle access through or <br />around a site involves changes in direction or curves, inside radius of 45 feet and <br />outside radius of 55 feet shall be provided to facilitate fire truck turning radius for entry <br />and exit from the site. Dead-end access ways and internal drives shall not exceed 300 <br />feet in length and shall terminate in cul-de-sacs no less than 96 feet in diameter or <br />hammer -head (tee). Standards and options are available through the Livermore - <br />Pleasanton Fire Department, Fire Prevention Bureau. <br />102. PREMISES IDENTIFICATION: Address numbers shall be installed on the front or <br />primary entrance for all buildings. Minimum building address character size shall be 12 - <br />inch high by 1 -inch stroke. In all cases address numerals shall be of contrasting <br />background and clearly visible in accordance with the Livermore -Pleasanton Fire <br />Department Premises Identification Standards. This may warrant field verification and <br />adjustments based upon topography, landscaping or other obstructions. <br />103. RESIDENTIAL — NEW CONSTRUCTION: The following items shall be provided prior to <br />any construction above the foundation or slab. <br />a. Emergency vehicle access shall be provided to the site (tract), including areas <br />where construction is occurring. <br />PUD -138 and VTM 8616 Page 21 of 25 <br />