My WebLink
|
Help
|
About
|
Sign Out
12
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2021
>
120721
>
12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2021 4:15:11 PM
Creation date
12/1/2021 4:14:18 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
12/7/2021
DESTRUCT DATE
15Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pleasanton PFAS Treatment & Wells Rehabilitation Project <br />City of Pleasanton <br />JDH Corrosion Consultants, Inc. 3 <br />the plans and profiles for the new water pipelines prepared by Carollo for construction details and <br />proposed pipeline materials and determine the suitability of the proposed materials based on the collected <br />field and laboratory data. <br /> <br /> <br />Task 3 – Final Design & Bid Documents <br /> <br />1. Prepare detailed design drawings, assuming a 30-year minimum design life. Prepare detailed installation <br />drawings for corrosion control for selected project alternative (pipe and well sites) including appropriate <br />stray current corrosion control, if needed. Review the proposed pipeline alignment for potential stray <br />current problems. Determine if the pipeline will parallel and cross any gas or other water pipelines as <br />each of these areas represent potential stray current problems. <br /> <br />Design drawings will be prepared in accordance with the project standards for 50%, 95%, and 100% <br />submittals. Design details will be prepared in AutoCAD Release 2018 format and electronically <br />transmitted to Carollo for inclusion into the project plans. <br /> <br />2. Prepare technical design specifications, assuming a 30-year minimum design life. <br /> <br />Technical design specifications will be prepared in accordance with the project standards for 50%, 95%, <br />and 100% submittals. Specifications will be prepared in Word format and e-mailed to Carollo for inclusion <br />into the project design documents. <br /> <br />3. Prepare detailed engineering cost estimate for supply of materials and installation of the proposed stray <br />current and cathodic protection systems. Engineering cost estimate will be prepared for 50%, 95% and <br />100% submittals. <br />
The URL can be used to link to this page
Your browser does not support the video tag.