NOTES
P18-0217, P18-0218, CUP & Design Review for Sonshine Preschool (Rondash), 1225 Hopyard Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
a. Electrical conduit and cable pull strings shall be installed from the roof/attic area to <br /> the building's main electrical panels; <br /> b. An area shall be provided near the electrical panel for the installation of an "inverter" <br /> required to convert the direct current output from the photovoltaic panels to <br /> alternating current; and <br /> c. Engineer the roof trusses to handle an additional load as determined by a structural <br /> engineer to accommodate the additional weight of a prototypical photovoltaic system <br /> beyond that anticipated for roofing. <br /> These measures shall be shown on the building permit plan set submitted to the <br /> Director of Community Development for review and approval before issuance of the <br /> building permit. <br /> Construction Practices and Noticing <br /> 17. WORK HOURS: All demolition and construction activities, inspections, plan checking, <br /> material delivery, staff assignment or coordination, etc., shall be limited to the hours of <br /> 8 a.m. to 5 p.m., Monday through Saturday. No construction shall be allowed on State <br /> or Federal Holidays or Sundays. The Director of Community Development may allow <br /> earlier "start times" or later "stop times" for specific construction activities, e.g., concrete <br /> pouring. All construction equipment shall meet Department of Motor Vehicles (DMV) <br /> noise standards and shall be equipped with muffling devices. Prior to construction, the <br /> hours of construction shall be posted on site. <br /> 18. CONSTRUCTION PARKING: Campers, trailers, motor homes, or any other similar <br /> vehicle are not allowed on the construction site except when needed as sleeping <br /> quarters for a security guard subject to receipt of a temporary conditional use permit <br /> (per PMC 18.116.010.E). <br /> 19. CONSTRUCTION TRAILERS: A construction trailer shall be allowed to be placed on <br /> the project site for daily administration/coordination purposes during the construction <br /> period. <br /> 20. PORTABLE TOILETS: Portable toilets used during construction shall be kept on the <br /> project site and as far as possible from existing residences and shall be emptied to <br /> prevent odor. <br /> 21 . DISTURBANCE COORDINATOR: The applicant shall designate a "disturbance <br /> coordinator" who shall be responsible for responding to any complaints regarding <br /> construction noise, dust, construction parking, etc. The coordinator (who may be an <br /> employee of the general contractor) shall determine the cause of the complaint and <br /> shall require the implementation of reasonable measures warranted to correct the <br /> problem. A telephone number of the disturbance coordinator shall be posted on the <br /> construction site fence and on the notification sent to neighbors adjacent to the site. The <br /> P18-0217 and P18-0218 Planning Commission <br /> Page 4 of 14 <br />OTOVOLTAIC SYSTEM: The building shall be constructed to allow for future <br /> installation of a photovoltaic (PV) system. The project applicant shall comply with the <br /> following requirements for making the building photovoltaic-ready: <br /> P18-0217 and P18-0218 Planning Commission <br /> Page 3 of 14 <br /><br /> nuisances as a result of the proposed use. <br />and <br />anta Rita Road Planning Commission <br /> Page 20 of 21 <br /> area shall drain into the trash <br /> PUD-125, 2350 Santa Rita Road Planning Commission <br /> Page 17 of 21 <br />25, 2350 Santa Rita Road Planning Commission <br /> Page 15 of 21 <br />g Commission <br /> Page 3 of 21 <br />