Laserfiche WebLink
The proposed project involves constructing up to three new multi-story buildings that <br /> would house a mix of R&D, office and laboratory uses, totaling approximately 381,000- <br /> square-feet, a parking structure, and related site improvements (e.g., landscape <br /> modifications, utility installation, stormwater treatment areas, etc.). The project is <br /> expected to develop over multiple phases, as seen in Attachment 2A in detail, Figure 2 <br /> later in this report, and described further below. <br /> Phase I, which the applicant would seek to develop in the near term (one- to two-years) <br /> includes the construction of an approximately 150,000-square-foot, two and three-story <br /> building (Building 1) at the northern portion of the subject site. This building would be <br /> 53-feet tall to the top of the parapet (65 feet tall with rooftop equipment screen). <br /> Approximately 483 surface parking spaces would be provided for Building 1 (equivalent <br /> to approximately 3.2 spaces per 1,000 sq. ft.). These parking spaces would utilize a <br /> portion of the existing surface-level parking lot on the subject site, which would be <br /> resurfaced/restriped and include upgraded lighting, landscaping, and new sidewalk <br /> access. Phase I would also include construction of a new plaza at the northeast portion <br /> of the subject site with pedestrian circulation connecting the proposed campus to <br /> Stoneridge Mall, BART, and adjacent office and residential developments, although this <br /> phase would be designed to facilitate pedestrian connections to internal open spaces <br /> (e.g.: a central campus courtyard with outdoor collaboration spaces for employees) and <br /> buildings developed in future phases of the project. The balance of the subject site <br /> would remain vacant under Phase I and be fenced temporarily and planted with native <br /> grasses. See Figure 3 below for additional detail. <br /> Subsequent phases, the timing of which is to be determined based on the business <br /> needs of 10x Genomics, but is expected to be complete by 2030, would include <br /> construction of up to an additional 231,000 square feet of building area within one or <br /> two additional buildings generally along the east side of the subject site. Attachment 2A <br /> shows these buildings in approximate locations, set back between 50 to 100 feet or <br /> more from all subject site frontages; however, Attachment 2A also shows a 32-foot <br /> minimum setback line, meaning these future buildings may be shifted anywhere within <br /> that minimum setback line as the applicant refines subsequent phases of their master <br /> plan. The applicant proposes the maximum height of these later phase buildings would <br /> be 67 feet to the top of the parapet (82 feet tall with rooftop equipment screen) (See <br /> Figure 12 later in this report for site section details). <br /> The later phases also include construction of a parking structure, providing 1,172 <br /> parking spaces, in six levels (five stories, plus rooftop parking) and 80 surface level <br /> parking spaces along the west side of the subject site. See Figure 4 below for additional <br /> detail. <br /> In the work session agenda report, staff indicated recorded agreements between the <br /> owners of the adjacent Stoneridge Mall and the subject site require minimum parking <br /> ratios of 4.0 spaces per 1,000 square feet to be provided on the subject site. However, <br /> the ratio required by the agreements is relatively high compared to the PMC's typical <br /> ratios for uses like those proposed and could potentially result in the project being <br /> 4 <br />