69. EMERGENCY RESPONDER RADIO: Emergency responder radio coverage shall be provided <br /> in accordance with section 510 of the Fire Code. <br /> 70. FIRE FLOW: Fire flow shall be in accordance with appendix B of the Fire Code with a 50- <br /> percent reduction for sprinklers. <br /> 71 . FIRE PROTECTION FACILITIES: Prior to any construction framing. the applicant shall provide <br /> adequate fire protection facilities. including, but not limited to a water supply and water flow in <br /> conformance to the City's Fire Department Standards able to suppress a major fire. <br /> 72. WATER FLOW AND CONTROL VALVES: All fire sprinkler system water flow and control valves <br /> shall be complete and serviceable prior to final inspection. Prior to the occupancy of a building <br /> having a fire alarm system, the Fire Department shall test and witness the operation of the fire <br /> alarm system. <br /> 73. ELECTRICAL CONDUIT: Electrical conduit shall be provided to each fire protection system <br /> control valve including all valve(s) at the water connections. The Livermore-Pleasanton Fire <br /> Department requires electronic supervision of all valves for automatic sprinkler systems and fire <br /> protection systems. <br /> 74. LISTED: All commercial, industrial, and multi-family residential occupancies shall have valve <br /> tamper and water flow connected to a listed Central Station Service in accordance with NFPA <br /> 72. Fire Department plan check includes specifications, monitoring, installation. and alarm <br /> company certificates. Fire alarm control panel and remote annunciation shall be at location(s) <br /> approved by the Fire Prevention Bureau. All systems shall be point identified by individual <br /> device and annunciated by device type and point. <br /> 75. HAZARDOUS MATERIALS: Should any operation or business activity involve the use, storage <br /> or handling of hazardous materials, the firm shall be responsible for contacting the Livermore- <br /> Pleasanton Fire Department prior to commencing operations. Please contact the Hazardous <br /> Materials Coordinator at 925/454-2361 . <br /> 76. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than 300 feet in <br /> industrial and commercial developments. Fire hydrants shall be installed at spacing not greater <br /> than 400 feet in residential developments. <br /> 77. FIRE LANE MARKING: On-site access ways. turn arounds. and internal drives shall be <br /> designated as fire lanes and identified as such by red curb striping and posted with signs at <br /> locations approve by the Fire Department. Signs shall be according to State standards and read <br /> "No Parking — Fire Lane" and must be shown on the plans. The red curb striping, sign <br /> location(s). and sign language shall be included in the building permit submittal for review and <br /> approval by the Livermore-Pleasanton Fire Department prior to building permit issuance. <br /> 78. FIRE VEHICLE ACCESS ROADS: Access roads shall have 13 feet. 6 inches unobstructed <br /> vertical clearance. 20 feet of unobstructed width (26 feet where occupied building floors exceed <br /> 30 feet height). and inside turning radius of 45 feet and outside turning radius of 55 feet. <br /> Unobstructed shall mean a clear travel way. excluding parking width. and designed for an <br /> emergency vehicle weight of 70.000 pounds under all weather conditions. Unobstructed width <br /> shall not include the width of rolled curbs. sidewalks, or non-drivable surfaces. <br /> 79. FIRE VEHICLE TURNAROUNDS: Where Fire Department vehicle access through or around a <br /> site involves changes in direction or curves. inside radius of 45 feet and outside radius of 55 feet <br /> shall be provided to facilitate fire truck turning radius for entry and exit from the site. Dead-end <br /> P19-0128/P19-0129 City Council <br /> Page 12 of 16 <br />