Laserfiche WebLink
The Pleasanton Municipal Code (PMC) does not explicitly address parking lifts, nor states <br /> whether they can be considered to provide required parking. Downtown Specific Plan Policy <br /> LD-P.20 requires the residential to be fully parked on-site; and, although the policy does not <br /> explicitly state as such, staffs interpretation of the policy is that for a project proposing new <br /> ground floor residential, existing parking (that is required by the PMC) cannot be removed to <br /> accommodate the residential project. The DSP does not specify how said parking is provided <br /> nor if alternative solutions (such as a parking lift) can be used to meet DSP Policy LD-P.20. <br /> Further discussion relating to parking and the proposed lift is provided below. <br /> Building Design <br /> The proposed building has a contemporary architectural style with horizonal lap siding (fiber <br /> cement), cantilevered second floors, a shed-style composition roof, and incorporates horizontal <br /> wood fencing and a CMU block wall at the carport. The building includes a second-story <br /> balcony and rooftop deck, as seen in Exhibit B and in Figure 6 below. <br /> Figure 6: Front Elevation <br /> ACCENT COLOR-1 --=-1.0.6T,:."4T12 <br /> DOCK CcIIgsea. AK)Wel \ i <br /> r <br /> i ,i <br /> 111111 <br /> .i .— <br /> 1 , III <br /> - • r� <br /> COLOR 4'`::';'*. <br /> �3l �f S r <br /> i Il <br /> r <br /> The applicant installed story poles for the proposed building as seen in Figures 7-8 below. The <br /> building will be visible from Ray Street directly in front of the property and from the adjacent <br /> properties. It will have limited and intermittent visibility when traveling on Ray due to existing <br /> buildings and vegetation. Full elevations are not included in the plans provided with this <br /> Preliminary Application but will be required for a formal application submittal. Further <br /> discussion about the building design is provided below. <br /> P20-0568, 218 Ray Street Planning Commission <br /> 6 of 11 <br />face parking (for the commercial building), and four spaces <br /> are provided in a parking lift. The lift is proposed to be located central to the lot behind the <br /> commercial building as seen in Exhibit B and Figure 3. The lift is proposed to be used by <br /> employees and essentially can lift two cars above two additional cars. Exhibit B provides a few <br /> renderings of the lift, as seen also below in Figures 4 and 5. Exhibit D also provides an exhibit <br /> of the lift and added lift details. <br /> One dwelling unit permitted per 1,000 square-feet <br /> 2 50 square-feet per bedroom for each bedroom in units with two or more bedrooms <br /> 3 Apartments with one or two bedrooms in the Core Area Overlay require a minimum of 1.5 spaces(rounds up to two)and 10 <br /> spaces are required for the 2,917 sq. ft. office building(one space per 300 square-feet) <br /> 4 Space count discussed below in the Considerations section of this report <br /> P20-0568, 218 Ray Street Planning Commission <br /> 4 of 11 <br />e-foot <br /> commercial office building toward the front, as seen on Sheet AS-1 of Exhibit B and Figures 1 <br /> and 2 below. There are currently 10 surface parking spaces located behind the office building <br /> which are accessed by a drive aisle on the east side of the building. <br /> P20-0568, 218 Ray Street Planning Commission <br /> 2 of 11 <br />