ii. The enclosure does not exceed 180 square feet in size <br />iii. The enclosure is stand-alone structure, be a minimum of 20 feet from adjacent <br />buildings and a minimum of 10 feet from property line(s). <br />iv. The enclosure is used exclusively for waste garbage contained within <br />approved trash containers. No outdoor storage is permitted within the trash <br />enclosure, <br />c. Photo Voltaic Arrays covering parking stalls only. <br />2. Existing commercial or industrial buildings not currently provided with automatic fire <br />extinguishing systems shall be provided with an automatic fire extinguishing systems as <br />follows: <br />a. When modification to the building results in a 50% or greater increase of the total floor <br />area of the building or brings the over total of floor area of the building to more than <br />8,000 square feet, the entire building shall be provided with an automatic fire <br />extinguishing system. <br />Exception: Additions providing accessory storage space not greater than 500 <br />square feet in area to an existing non -fire sprinklered building or solely for the <br />purpose of providing accessibility shall not result in a requirement that the building <br />be provided with an automatic extinguishing system. <br />b. When a change in occupancy classification results in an increased fire hazard or risk <br />to business operations or increased life safety hazard of the occupants, the new <br />occupancy and all fire areas that the new occupancy exits through shall be provided <br />with an automatic extinguishing system. <br />Exception: Public assembly occupancies not exceeding an occupant load of 150, <br />whether occupying an entire building or a portion of a building. <br />3. Existing residential buildings not currently provided with automatic fire extinguishing systems <br />shall be provided with an automatic fire extinguishing systems as follows: <br />a. When a modification or modifications to the building results in a 50% or greater <br />increase of the total floor area of the building <br />b. In the garage when a new attached or detached garage is added and the modification <br />does not otherwise require the addition of an automatic fire protection system <br />throughout the building. <br />20.24.170 CFC Section 903.3.1.2 amended —NFPA 13R Sprinkler Systems. <br />Section 903.3.1.2 paragraph 1 is amended to read: <br />903.3.1.2 NFPA 13R sprinkler systems. Automatic sprinkler systems in Group R occupancies <br />up to and including four stories in height in buildings not exceeding 60 feet (18 288 mm) in height <br />above grade plan shall be permitted to be installed throughout in accordance with NFPA 13R as <br />amended in Chapter 80 and the following: <br />• Sprinklers shall be provided in all attic areas. <br />20.24.180 CFC Section 903.3.1.3 amended —NFPA 13D Sprinkler Systems. <br />Section 903.3.1.3 is amended to read: <br />Page 30 of 52 <br />