Laserfiche WebLink
Table column title MINIMUM TOTAL LENGTH (FEET) OF BRACED WALL PANELS REQUIRED <br />ALONG EACH BRACED WALL LINE is amended to add footnote "a". <br />Footnote "g" is added, to read as follows: <br />g. Method CS-SFB and Method GB are not permitted, and the use of Method PCP is limited <br />to one-story single-family dwellings and accessory structures. <br />20.10.070 <br />CRC Section R602.10.4.5 added —Limits on methods GB and PCP. <br />Section �9�1-9-4� R602.10.4.5 is added, to read as follows: <br />4. Method GB is not permitted for use as intermittent braced wall panels, but gypsum board <br />is permitted to be placed on the opposite side of the studs from other types of braced wall <br />panel sheathing. The use of Method PCP is limited to one-story single-family dwellings <br />and accessory structures. <br />20.10.080 . <br />CRC Section R902.1 amended —Roofing covering materials. <br />Section R902.1 is amended to read as follows: <br />R902.1 Roofing covering materials. Roofs shall be covered with materials as set forth in <br />Sections R904 and R905. A minimum Class B roofing, listed and tested in accordance with UL <br />790 or ASTM E108, is required in the City of Pleasanton. <br />Page 19 of 52 <br />