My WebLink
|
Help
|
About
|
Sign Out
3_Exhibits A & C-F
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2010-2019
>
2019
>
09-25
>
3_Exhibits A & C-F
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2019 11:36:05 AM
Creation date
9/18/2019 11:35:12 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
9/25/2019
Document Relationships
3
(Message)
Path:
\BOARDS AND COMMISSIONS\PLANNING\AGENDA PACKETS\2010-2019\2019\09-25
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
emergency vehicle weight of 70,000 pounds under all weather conditions. Unobstructed width <br /> shall not include the width of rolled curbs, sidewalks, or non-drivable surfaces. All exterior <br /> portions of buildings must be within 200 feet of an access road. Yard and parking area may be <br /> able to be located farther than 200 feet from access roads, depending on the specific use. <br /> 91. FIRE VEHICLE TURNAROUNDS: Where Fire Department vehicle access through or around a <br /> site involves changes in direction or curves, inside radius of 45 feet and outside radius of 55 feet <br /> shall be provided to facilitate fire truck turning radius for entry and exit from the site. Dead-end <br /> access ways and internal drives shall not exceed 300 feet in length and shall terminate in cul-de- <br /> sacs no less than 96 feet in diameter or hammer-head (tee). Standards and options are available <br /> through the Livermore-Pleasanton Fire Department, Fire Prevention Bureau. <br /> 92. PREMISES IDENTIFICATION: Address numbers shall be installed on the front or primary <br /> entrance for all buildings. Minimum building address character size shall be 12-inch high by 1- <br /> inch stroke. In all cases address numerals shall be of contrasting background and clearly visible <br /> in accordance with the Livermore-Pleasanton Fire Department Premises Identification Standards. <br /> This may warrant field verification and adjustments based upon topography, landscaping or other <br /> obstructions. <br /> 93. COMMERCIAL — NEW CONSTRUCTION: The following items shall be provided prior to any <br /> construction above the foundation or slab. <br /> a. Emergency vehicle access shall be provided to the site, including areas where <br /> construction is occurring. If Public Works Improvements are part of the project to <br /> access the site, an emergency vehicle access plan shall be submitted for review and <br /> approval to the Fire Department. <br /> b. If permanent access or site paving is not provided, the carrying capacity of the <br /> emergency vehicle access shall be 70,000 pounds under all weather conditions. <br /> c. Site staging area(s) shall be provided for materials and equipment. All staging areas <br /> shall be outside of the emergency vehicle access route shown on the approved plans. <br /> d. Where on-site fire hydrant(s) are required, they shall be installed, flushed and all <br /> valves open prior to any construction above the foundation or slab. This includes <br /> concrete tilt-up and masonry buildings. <br /> e. On-site fire hydrant(s) shall not be obstructed and shall be sufficiently above grade to <br /> have all hydrant valves and outlets accessible for emergency use. <br /> f. Where a project is phased as part of the development, specific access, water supply <br /> and fire hydrant installations will be required as part of each phase. As needed a <br /> phasing plan with these improvements will be required. <br /> g. Where on-site grading/utility plans are submitted for review and approval prior to <br /> building construction drawings, emergency vehicle access routes, fire hydrant <br /> locations, material staging areas, etc. shall be provided. <br /> 94. FINAL INSPECTION: Prior to request for final inspection, all access roads, on-site access and <br /> fire hydrants shall be provided. All fire hydrants shall be accepted, inspected and tested to <br /> applicable City Standards. <br /> LANDSCAPE ARCHITECTURE DIVISION — 925-931-5672 <br /> Landscaping <br /> 95. LANDSCAPING: Detailed landscape and irrigation plans encompassing all planting areas, both <br /> on-site and off-site, shall be included in the building permit plans. All plans shall be prepared by a <br /> licensed landscape architect and shall provide the species, location, size, quantities, and spacing <br /> P16-1349 and PUD-121 Planning Commission <br /> Page 14 of 19 <br />ructed to prevent stormwater run-on and runoff and to contain litter and <br /> trash, so that it is not dispersed by the wind or runoff during waste removal. The area enclosed <br /> shall drain to the sanitary sewer system and an area drain shall be installed in the enclosure area, <br /> providing a structural control such as an oil/water separator or sand filter. No other area shall <br /> P16-1349 and PUD-121 Planning Commission <br /> Page 11 of 19 <br />