My WebLink
|
Help
|
About
|
Sign Out
4_Exhibit A
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2010-2019
>
2019
>
08-28
>
4_Exhibit A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2019 3:43:37 PM
Creation date
8/21/2019 3:43:23 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
8/28/2019
Document Relationships
4
(Message)
Path:
\BOARDS AND COMMISSIONS\PLANNING\AGENDA PACKETS\2010-2019\2019\08-28
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ENGINEERING DEPARTMENT — LAND DEVELOPMENT — 925-931-5650 <br /> Design <br /> 56. The demolition plan shall depict all trees, and their tree numbers, to be removed and saved. <br /> (Project Specific Condition) <br /> 57. The applicant shall submit a grant deed, plat and legal description for the two-foot wide right-of- <br /> way dedication to the City of Pleasanton along the West Las Positas Boulevard frontage as <br /> determined by the City Traffic Engineer. The applicant shall submit the grant deed, plat and legal <br /> description with the first submittal of the building permit plans. (Project Specific Condition) <br /> 58. All unused utility laterals shall be abandoned in compliance with the City of Pleasanton Standard <br /> Specifications and Details dated November 2016. (Project Specific Condition) <br /> 59. The pump station area shall be designed to meet the current NPDES Permit requirements <br /> including but not limited to containing the accidental spill, canopy overhang, run on and run off <br /> from the area under the pump station canopy, trash capture, etc. (Project Specific Condition) <br /> 60. The Utility and Storm Drain Plan submitted for issuance of a building permit shall include the <br /> proposed fire service in compliance with the City of Pleasanton Standard Drawing 708 and shall <br /> be subject to the review and approval of the Fire Marshall. (Project Specific Condition) <br /> 61. The Utility and Storm Drain Plan submitted for issuance of a building permit shall depict the <br /> locations, sizes, serial numbers and GPM ratings of the existing and proposed water meters and <br /> locations of the proposed backflow devices. The proposed water meters shall be sized based on <br /> the domestic water demand shown on the plumbing plans and the irrigation water demand shown <br /> on the irrigation plans. (Project Specific Condition) <br /> 62. The planting within the bioretention areas shall be designed and constructed in compliance with <br /> Appendix B, Plant List and Planting Guidance for Landscape-Based Stormwater Measures in the <br /> Alameda County Cleanwater Program's C.3 Stormwater Technical Guidance dated May 2, 2016, <br /> and as required by the City Landscape Architect. (Project Specific Condition) <br /> 63. The improvement plans shall depict the reconstruction of deficient sidewalk: approximately 35 <br /> linear feet of sidewalk along the West Las Positas Boulevard frontage and approximately four <br /> linear feet of sidewalk located 30 feet southeasterly of the curb ramp on West Las Positas <br /> Boulevard. (Project Specific Condition) <br /> 64. The driveways at the project site shall be designed and constructed in compliance with current <br /> ADA requirements. (Project Specific Condition) <br /> 65. All retaining walls and footings along West Las Positas Boulevard and Hopyard Road shall be <br /> located behind the existing public service easement and/or proposed or existing public right of <br /> way, unless otherwise approved by the Director of Engineering/City Engineer. All retaining walls <br /> with a minimum height of 4 feet, measured from the bottom of the footing to the finished grade at <br /> the top of the wall, and all retaining walls with a surcharge shall be designed by a California <br /> licensed civil or structural engineer. (Project Specific Condition) <br /> PUD-134/P18-0332/P18-0334 Planning Commission <br /> Page 9 of 19 <br /> Planning Commission <br /> Page 8 of 19 <br />or the excavation, or <br /> to their authorized representative. A similar note shall appear on the building permit and/or <br /> improvement plans. <br /> PUD-134/P18-0332/P18-0334 Planning Commission <br /> Page 6 of 19 <br /> review and approval by the City Traffic Engineer and Director of Community <br /> Development prior to issuance of a demolition permit, or the first building permit, whichever <br /> PUD-134/P18-0332/P18-0334 Planning Commission <br /> Page 5 of 19 <br />