My WebLink
|
Help
|
About
|
Sign Out
PC-2019-11
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2010-2019
>
2019
>
PC-2019-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2019 12:58:07 PM
Creation date
7/25/2019 3:45:21 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
6/12/2019
DESTRUCT DATE
PERMANENT
DOCUMENT NO
PC-2019-11
NOTES
P19-0048_P19-0049, EMPIRE MONTESSORI, 5950 STONERIDGE DRIVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
24. FIRE ALARM: The applicant shall install a fire alarm system. Prior to the occupancy of a <br /> building, the Fire Department shall test and witness the operation of the fire alarm system. <br /> Project Specific Condition. <br /> 25. SITE SAFETY: Site safety during construction shall be in accordance with Fire Code chapter <br /> 33. <br /> LANDSCAPE ARCHITECTURE DIVISION —925-931-5672 <br /> Landscaping <br /> 26. LANDSCAPING: Detailed landscape and irrigation plans encompassing all planting areas, both <br /> on-site and off-site, shall be included in the building permit plans. All plans shall be prepared by <br /> a licensed landscape architect and shall provide the species, location, size, quantities, and <br /> spacing of all plants. Minimum plant sizes are 1-gallon containers for ground cover, 5-gallon <br /> containers for shrubs, 15-gallon containers for trees outside of the public service easement <br /> (PSE), and 24-inch box containers for trees within the PSE. Plant species shall be of a drought- <br /> tolerant nature and the irrigation design shall utilize low-volume drip, bubbler, or other water <br /> conserving irrigation systems to the maximum extent possible. The drawings shall be subject to <br /> the review and approval of the City Landscape Architect prior to building permit issuance. <br /> Project Specific Condition. <br /> 27. WATER EFFICIENT LANDSCAPE ORDINANCE (WELD): The project shall comply with the <br /> City of Pleasanton's Water Efficient Landscape Ordinance (WELO) and Bay Friendly Basics <br /> Landscape Checklist. The applicant shall submit a Landscape Documentation Package in PDF <br /> format to the Landscape Architecture Division, which shall be subject to review and approval by <br /> the City Landscape Architect prior to building permit issuance. The Landscape Documentation <br /> Package shall include: <br /> a. Project Information; <br /> b. Water Efficient Landscape Worksheet; <br /> c. Soil management report; <br /> d. Landscape design plan; <br /> e. Irrigation design plan; and <br /> f. Grading design plan. <br /> 28. CERTIFICATE OF COMPLETION: Upon completion of construction and prior to final inspection <br /> by the Building and Safety Division, the applicant's landscape architect shall submit a Certificate <br /> of Completion Package in PDF format to the Landscape Architecture Division for review and <br /> approval. The Certificate of Completion Package shall include: <br /> a. Project information sheet; <br /> b. Certificate of installation according to the landscape documentation package; <br /> c. Irrigation scheduling; <br /> d. Schedule of irrigation, landscape and irrigation maintenance; <br /> e. Landscape irrigation audit report; and <br /> f. Soil management report (if not previously submitted). <br /> 29. LANDSCAPING INSTALLATION: Prior to building permit final, all landscaping as shown on the <br /> approved building permit set, shall be reviewed, approved, installed, and inspected by the <br /> Landscape Architecture Division. <br /> P19-0048 and P19-0049 Planning Commission <br /> Page 4 of 7 <br /> Page 3 of 7 <br /> posted on site. <br /> Conditional Use Permits <br /> 11. CAPACITY: Empire Montessori shall be limited to a maximum of 120 preschool students and 18 <br /> administrators/staff/volunteers on-site at any given time. Project Specific Condition <br /> P19-0048 and P19-0049 Planning Commission <br /> Page 2 of 7 <br />emicals, or other harmful materials shall be deposited or disposed <br /> within the dripline of the trees or in drainage channels, swales, or areas that may lead to <br /> the dripline. <br /> P19-0048 and P19-0049 Planning Commission <br /> Page 6 of 7 <br />or security may be <br /> released early with a certification letter by the arborist confirming he/she was present during <br /> said tree work and work was performed in accordance with the arborist's recommendations. <br /> P19-0048 and P19-0049 Planning Commission <br /> Page 5 of 7 <br />