Laserfiche WebLink
FIRE DEPARTMENT — 925-454-2361 <br /> The Fire Prevention Bureau reviews building/civil drawings for conceptual on-site fire mains and fire <br /> hydrant locations only. Plan check comments and approval DO NOT include: 1.) Installation of the <br /> on-site fire mains and fire hydrants. Specific installation drawings submitted by the licensed <br /> underground fire protection contractor shall be submitted to the Fire Prevention Bureau for approval; <br /> and 2.) Backflow prevention or connections to the public water mains. <br /> 60. TURN-AROUND: The on-site Fire Department turn-around is required and cannot be modified <br /> from the approved plans without prior approval from the Fire Department. (PROJECT <br /> SPECIFIC CONDITION) <br /> 61. FIRE HAZARDS: The project developer shall keep the site free of fire hazards from the start of <br /> lumber construction until the final inspection. <br /> 62. FIRE CODE: All construction shall conform to the requirements of the 2016 Pleasanton Fire <br /> Code and local ordinances. All required permits shall be obtained prior to work commencement. <br /> 63. SITE SAFETY: Site safety during construction shall be in accordance with Fire Code chapter <br /> 33. <br /> 64. FIRE SPRINKLERS: Automatic fire sprinklers shall be installed in all occupancies in accordance <br /> with the 2016 Pleasanton Building, Fire and Residential Codes with local amendments and <br /> ordinances. <br /> 65. HAZARDOUS MATERIALS: Should any operation or business activity involve the use, storage <br /> or handling of hazardous materials, the firm shall be responsible for contacting the <br /> Livermore-Pleasanton Fire Department prior to commencing operations. Please contact the <br /> Hazardous Materials Coordinator at 925/454-2361. <br /> 66. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 inches <br /> unobstructed vertical clearance, 20 feet of unobstructed width (26 feet where occupied building <br /> floors exceed 30 feet height), and inside turning radius of 31 feet and outside turning radius of <br /> 51 feet. Unobstructed shall mean a clear travel way, excluding parking width, and designed for <br /> an emergency vehicle weight of 70,000 pounds under all weather conditions. Unobstructed <br /> width shall not include the width of rolled curbs, sidewalks, or non-drivable surfaces. All exterior <br /> portions of buildings must be within 200 feet of an access road. Yard and parking area may be <br /> able to be located farther than 200 feet from access roads, depending on the specific use. <br /> 67. PREMISES IDENTIFICATION: Address numbers shall be installed on the front or primary <br /> entrance for all buildings. Minimum building address character size shall be 12-inch high by <br /> 1-inch stroke. In all cases address numerals shall be of contrasting background and clearly <br /> visible in accordance with the Livermore-Pleasanton Fire Department Premises Identification <br /> Standards. This may warrant field verification and adjustments based upon topography, <br /> landscaping or other obstructions. <br /> 68. RESIDENTIAL — NEW CONSTRUCTION: The following items shall be provided prior to any <br /> construction above the foundation or slab. <br /> a. Emergency vehicle access shall be provided to the site (tract), including areas where <br /> construction is occurring. <br /> P18-0109 Planning Commission <br /> Page 10 of 13 <br />IFIC CONDITION) <br /> 59. BIORETENTION: The project Geotechnical Engineer shall review and approve the location of <br /> the bioretention area on the downstream of the house. The bioretention area may require a <br /> structural wall with the exposed wall finish subject to the review and approval of the Planning <br /> Division. (PROJECT SPECIFIC CONDITION) <br /> P18-0109 Planning Commission <br /> Page 9 of 13 <br /> P18-0109 Planning Commission <br /> Page 5 of 13 <br />be a signatory to any lease for the rented units. (PROJECT <br /> SPECIFIC CONDITION) <br /> P18-0109 Planning Commission <br /> Page 4 of 13 <br />