Laserfiche WebLink
•MCPARLANE THE CENTURY HOUSE <br />&ASSOCIATES <br />• PLEq$AIVTON, Ci/4 <br />CONSULTING MMIANICALENGINUM <br />ULT <br />• Kitchen Hood & Duct: <br />-o Existing: Residential style located above stove ducted to exterior; fan located <br />in hood. <br />o Condition: Fair, not code compliant for commercial non-residential facility - <br />o Recommendation: Remove; do not replace hood, duct, or stove. <br />• Second Level HVAC: <br />o Existing:. Nonexistent.. <br />o Condition: N/A. <br />o Recommendation: Add new ceiling mounted split system unit with -heating <br />and cooling to serve two rooms at upper level. Unit may be mounted above <br />corridor and ducted to each room. Controls to be located inone room. <br />• Other HVAC Notes: <br />o If .occupancy increase is anticipated, all existing equipment, ductwork, and <br />registers shall require removal and replacement with multiple units with <br />increased. capacity and ducted outside air provisions. <br />o All systems to be tested and balanced -prior to occupancy. <br />B. Plumbing Systems: <br />• Fixtures: <br />o. Existing: Flush tank water closets, flush valve urinal, counter mounted <br />lavatory, kitchen sink (stainless steel), and plastic mop sink. <br />.o Condition: Poor. Water closet,, urinal; lavatory, and sink appear non- <br />compliant with current ADA and CalGreen standards. <br />o Recommendation: Remove and replace with new. <br />'Garbage Disposal: <br />o Existing: Under counter, switch .operated. <br />Model No. "Insinkerator" 5-75.1/2 HP. <br />o Condition: Non -operational. <br />o . Recommendation: Replace with new. <br />• Water Heater: <br />.,o . Existing: Day.and Night. <br />Model No. 20-J-1. <br />Capacity: 20=gallon; 30,000 BTUH, 25.2 GPM recovery. <br />o Condition: Poor, rusted, improperly supported. <br />o Recommendation: Replace with new; provide seismic support and base. <br />drain plan. <br />DUE DILIGENCE REPORT PAGE 5 OF 13 <br />