Laserfiche WebLink
<br />Resolution No. PC-99-32 <br />Page 10 <br /> <br />40. The site shall be kept free of fire hazards from the start of construction to final <br />inspection. <br /> <br />BUILDING DEPARTMENT CONDITIONS <br /> <br />41. All building and/or structural plans must comply with all codes and ordinances in <br />effect before the Building Department will issue permits. <br /> <br />42. Building and situs plans are to be submitted to the Building Department on <br />computer disk in a format approved by the Director. Digitized information shall <br />be submitted before requesting a final inspection and should reflect as-built situs <br />and architectural information as approved by the Director. <br /> <br />43. The developer shall submit a building survey and/or a record of survey and a site <br />development plan in accordance with the provisions of Chapter 18.68 of the <br />Municipal Code of the City of Pleasant on. These plans shall be approved by the <br />Director of Building Inspection prior to the issuance of a building permit. The site <br />development plan shall include all required information to design and construct <br />site, grading, paving, drainage and utilities. Specific items to be indicated on the <br />site development plan necessary to construct the improvements are to be in <br />accordance with the City of Pleasant on Private Development Design Guidelines <br />adopted April 15, 1986. <br /> <br />44. The developer shall submit two copies of the site soils report to the Director of <br />Building Inspection for third party peer review and shall pay for such review at the <br />time specified by the Director, but in all cases before the issuance of a grading <br />permit. <br /> <br />45. The soils engineer shall certify the pad compaction of any fill areas to the <br />satisfaction of the Director of Building Inspection prior to the issuance of building <br />permits. <br /> <br />46. All retaining walls higher than four feet from the top of the wall to the bottom of <br />the footway shall be constructed of reinforced concrete or shall be an approved <br />crib wall type. Calculations signed by a registered civil engineer shall accompany <br />the wall plans. <br /> <br />47. The paving sections for the on-site parking and drive areas shall be designed on the <br />basis of an R-Value test and a traffic index to carry the anticipated traffic loads. <br />This design shall be subject to the approval ofthe Director of Building Inspection. <br />The minimum paving section shall be 2" A.C. on 6" of A.B. The minimum A.C. <br />pavement slope shall be 1 %. For pavement slopes of less than 1 %, the surface <br />