My WebLink
|
Help
|
About
|
Sign Out
ORD 0655
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
0601 - 0700
>
ORD 0655
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2004 10:37:32 AM
Creation date
10/15/1999 11:01:23 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT NO
ORD 0655
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
~i 7) The anticipated overall drainage of the <br /> pool site; and <br /> <br /> 8) The proposed fencing; <br /> <br /> (b) A structural plan showing at least the <br /> <br /> following: <br /> <br /> 1) The type of construction, whether gunite, <br /> <br /> poured concrete, prefabricated, or other; <br /> <br /> 2) The pool dimensions, including the depth, <br /> <br /> and adequate cross-sections drawn to scale; <br /> <br /> 3) The reinforcing steel schedule and detail; <br /> <br /> 4) A statement concerning the anticipated <br /> <br /> nature of the soil under and around the pool structure. A <br /> <br /> soil condition report shall be submitted where required by the <br /> administrative authority. In lieu of a soil report an expansive so'~ <br /> ;teel schedule may be used. <br /> <br />~l 5) The interior finish details~ <br />,, <br /> <br /> 6) The pool edge details~ and <br /> <br /> 7) Computations, stress diagrams, and other <br /> <br /> data sufficient to show the correctness of the plans~ and <br /> <br /> (c) A mechanical plan showing at least the <br /> <br /> following: <br /> <br /> 1) The volume, system flow rate in gallons <br /> <br /> ~er minute, and turnover in hours; <br /> <br /> 2) The type and size of filtration system; <br /> 3) The type and size of pool heater, if <br /> included, including the method of venting and provisions for <br /> zombustion air; <br /> <br /> 4) The pool piping layout with all sizes <br /> <br /> shown and types of meterial to be used, and showing the location <br /> <br /> ~n the main outlet, surface skimmers, and inlets~ <br /> <br /> 5) The rated capacity of the pool pump in <br /> <br /> G.P.M. at the design head with the size and type of motor indi- <br /> <br /> cated and identified as self-priming or straight centrifugal; <br />il <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.