My WebLink
|
Help
|
About
|
Sign Out
ORD 2153
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2101 - 2200
>
ORD 2153
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:25 PM
Creation date
12/1/2016 1:39:47 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
11/15/2016
DESTRUCT DATE
PERMANENT
DOCUMENT NO
2153
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section AJ301 2 is amended to be read as follows <br /> AJ301.2 Water closets. Where any water closet is replaced with a newly manufactured <br /> water closet, the replacement water closet shall comply with the requirements of the <br /> California Plumbing Code Section 411 0 <br /> 20.10.110 CRC Appendix J Section AJ301.3 amended — Electrical. <br /> Section AJ 102 4 1 is amended to be read as follows <br /> AJ301 Electrical Repair or replacement of electrical wiring and equipment undergoing <br /> repair with like material shall be permitted <br /> Exceptions: <br /> 1 Replacement of electrical receptacles shall comply with the requirements in <br /> the California Electrical Code, Title 24 Part 5 <br /> 2 Plug fuses of the Edison-base type shall be used for replacements only <br /> where there is not evidence of overfusing or tampering in accordance with <br /> the applicable requirements in the California Electrical Code, Title 24 Part 5 <br /> 3 For replacement of nongrounding-type receptacles with grounding-type <br /> receptacle and for branch circuits that do not have an equipment grounding <br /> conductor in the branch circuitry, the grounding conductor of a grounding- <br /> type receptacle outlet shall be permitted to be grounded to any accessible <br /> point on the grounding electrode system, or to any accessible point on the <br /> grounding electrode conductor, as allowed and described in the California <br /> Electrical Code, Title 24 Part 5 <br /> 20.10.120 CRC Appendix J Section AJ401.4 amended — Structural. <br /> Section AJ401 4 is amended to be read as follows <br /> AJ401.4 Structural. Unreinforced masonry buildings shall have parapet bracing and wall <br /> anchors of an approved design <br /> 20.10.130 CRC Appendix J Section AJ501.5.1 amended — Electrical equipment <br /> and wiring. <br /> Section AJ501 5 1 is amended to be read as follows <br /> AJ501.5.1 Materials and methods. Newly installed electrical equipment and wiring <br /> relating to work done in any work area shall comply with the materials and methods <br /> requirements of the California Electrical Code, Title 24 Part 5 <br /> Exception: Electrical equipment and wiring in newly installed partitions and ceilings <br /> shall comply with the applicable requirements of the California Electrical Code, Title <br /> 24 Part 5 <br /> 20.10.140 CRC Appendix J Section AJ501.5.3.3 amended — Ground-fault circuit- <br /> interruption. <br />
The URL can be used to link to this page
Your browser does not support the video tag.