My WebLink
|
Help
|
About
|
Sign Out
ORD 2153
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2101 - 2200
>
ORD 2153
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:25 PM
Creation date
12/1/2016 1:39:47 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
11/15/2016
DESTRUCT DATE
PERMANENT
DOCUMENT NO
2153
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 Fire sprinklers shall be provided in garages Fire sprinklers shall be intermediate <br /> rated, quick response type, with a maximum coverage area of 130 square feet per <br /> sprinkler <br /> R313.2 Large One- and Two-Family Dwelling Residential Sprinkler Systems. In <br /> addition to the requirements specified in R313 1, one- and two- family dwellings with a <br /> habitable floor area greater than 7,500 square feet shall have an automatic fire-sprinkler <br /> system designed to include all sprinklers within a compartment, up to a maximum of four <br /> sprinklers <br /> 20.10.060 CRC Table R602.10.3(3) amended — Bracing Requirements based on <br /> Seismic Design Category. <br /> Table R602 10 3(3) footnote "e" is is amended to read as follows <br /> e Method CS-SFB and Method GB are not permitted, and the use of Method PCP is <br /> limited to one-story single family dwellings and accessory structures <br /> 20.10.070 CRC Section R602.10.4.4 added — Limits on methods GB and <br /> PCP. <br /> Section R602 10 4 is amended to add section R602 10 4 4 to read as follows <br /> R602.10.4.4 Limits on methods GB and PCP. Method GB is not permitted for use as <br /> intermittent braced wall panels, but gypsum board is permitted to be installed when required <br /> by this Section to be placed on the opposite side of the studs from other types of braced <br /> wall panel sheathing The use of Method PCP is limited to one-story single family dwellings <br /> and accessory structures <br /> 20.10.080 CRC Section R907.7 amended — Fire Classification. <br /> Section R902 1 is amended to read as follows <br /> R902.1 Roofing covering materials. Roofs shall be covered with materials as set forth in <br /> Sections R904 and R905 A minimum Class B roofing shall be installed in the City of <br /> Pleasanton Roofing required by this section shall be listed shall be tested in accordance <br /> with UL 790 or ASTM E108 <br /> 20.10.090 CRC Appendix J Section AJ102.4.1 amended — Energy efficiency. <br /> Section AJ102 4 1 is amended to be read as follows <br /> AJ102.4.1 Energy efficiency. Replacement windows shall comply with the fenestration <br /> requirements in the California Energy Code, Title 24 Part 6 <br /> 20.10.100 CRC Appendix J Section AJ301.2 amended —Water closets. <br />
The URL can be used to link to this page
Your browser does not support the video tag.