My WebLink
|
Help
|
About
|
Sign Out
ORD 2135
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2101 - 2200
>
ORD 2135
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:25 PM
Creation date
2/3/2016 1:19:18 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
1/19/2016
DESTRUCT DATE
PERMANENT
DOCUMENT NO
2135
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Installation of the on -site fire mains and fire hydrants. Specific installation drawings <br />submitted by the licensed underground fire protection contractor shall be submitted <br />to the Fire Prevention Bureau for approval. <br />• Backflow prevention or connections to the public water mains. <br />104. Electrical conduit shall be provided to each fire protection system control valve including <br />all valve(s) at the water connections. The Livermore- Pleasanton Fire Department <br />requires electronic supervision of all valves for automatic sprinkler systems and fire <br />protection systems. <br />105. Address numbers shall be installed on the front or primary entrance for all buildings. <br />Minimum building address character size shall be 12 inches high by 1 -inch stroke. If <br />building is located greater than 50 feet from street frontage, character size shall be 16 <br />inches high by 1 % inches stroke minimum. Where multiple access is provided, address <br />or tenant space number shall be provided on each access and /or warehouse door and <br />character size shall be no Tess than 4 inches high by 34-inch stroke. In all cases address <br />numerals shall be of contrasting background and clearly visible in accordance with the <br />Livermore - Pleasanton Fire Department Premises Identification Standards. This may <br />warrant field verification and adjustments based upon topography, landscaping or other <br />obstructions. conditions of approval checklist shall be completed and attached to all <br />plan checks submitted for approval indicating that all conditions have been satisfied. <br />106. The following items will be provided prior to any construction above the foundation or <br />slab. NOTE: Periodic inspections will be made for compliance. <br />a. Emergency vehicle access will be required to be provided to the site (tract), including <br />the area where construction is occurring. <br />b. Multi- family residential developments: Projects having more than 100 dwelling units <br />shall be equipped throughout with two separate and approved fire apparatus access <br />roads. <br />c. Emergency vehicle access shall be a minimum of 20 feet in clear width. A clear <br />height free of obstructions (power, cable, telephone lines, tree limbs, etc.) is <br />required. This clearance shall be a minimum of 13 feet -6 inches. Inside tuming <br />radius of 45 feet and outside turning radius of 55 feet shall be provided. <br />d. Buildings or portions of buildings or facilities exceeding 30 feet (9144 mm) in height <br />above the lowest level of fire department vehicle access shall be provided with <br />approved fire apparatus access roads capable of accommodating fire department <br />aerial apparatus. Fire apparatus access roads shall have a minimum unobstructed <br />width of 26 feet in the immediate vicinity of any building or portion of building more <br />than 30 feet (9144 mm) in height. At least one of the required access routes meeting <br />this condition shall be located within a minimum of 15 feet (4572 mm) and a <br />maximum of 30 feet (9144 mm) from the building, and shall be positioned parallel to <br />one entire side of the building. <br />P14 -0124, P14 -0125, and PUD- 107/377 St. Mary Street Planning Commission <br />18 of 26 <br />
The URL can be used to link to this page
Your browser does not support the video tag.