Laserfiche WebLink
Traffic Division <br /> 57. The applicant shall design and install all needed modifications to the traffic signal <br /> system at the intersection of West Las Positas Boulevard at Hacienda Drive to <br /> provide full eight phase operation with protected left turns. This includes: <br /> • modifying the south leg of the intersection to provide one left turn and one <br /> shared through/right turn lane <br /> • modifying the north leg of the intersection to provide one left turn lane, one <br /> through lane, and one right turn lane and modification to the roadway median <br /> to reduce the through lane offset. <br /> • all needed changes to signal heads and equipment <br /> • upgrade of vehicle detection system to current standards including bicycle <br /> detection <br /> • provide accessible pedestrian push buttons <br /> • intersection striping and signing <br /> • any additional modifications needed to upgrade traffic signal system to <br /> current standards <br /> 58. Comprehensive traffic control measures shall be <br /> implemented during construction, including scheduling of major truck trips and <br /> deliveries, to avoid peak travel hours. If necessary, as determined by the Traffic <br /> Engineer, proper lane closure procedures such as flagger stations, signage, cones, <br /> and other warning devices shall be implemented during construction. <br /> Livermore-Pleasanton Fire Department <br /> 59. The buildings covered by this approval shall be equipped with an automatic fire <br /> sprinkler system. Plans and specifications for the automatic fire sprinkler system <br /> shall be submitted for review and approval by the Livermore-Pleasanton Fire <br /> Department prior to installation. The fire alarm system, including water flow and <br /> valve tamper, shall have shop drawings submitted for review and approval by the <br /> Livermore-Pleasanton Fire Department prior to installation. All required <br /> inspections and witnessing of tests shall be completed prior to final inspection and <br /> occupancy of the building(s). <br /> 60. Valve tamper and water flow shall be monitored by an approved supervising <br /> station in accordance with NFPA 72 and the California Fire Code. Fire alarm <br /> control panel and remote annunciation panel(s) shall be at location(s) approved by <br /> the Fire Prevention Bureau. All systems shall be point identified by individual <br /> device, monitored, and annunciated by device type and point. <br /> 61. Access for this project is acceptable by the Fire Marshal as currently shown on the <br /> PUD development plan. Unless otherwise approved by the Fire Marshal, the <br /> applicant/developer shall not modify the site access that deviates from the <br /> following requirements: Buildings or portions of buildings or facilities exceeding 30 <br /> 10of28 <br />