110. The Fire Prevention Bureau reviews building /civil drawings for conceptual on -site <br />fire mains and fire hydrant locations only. Plan check comments and approvals <br />DO NOT INCLUDE: <br />• Installation of the on -site fire mains and fire hydrants. Specific installation <br />drawings submitted by the licensed underground fire protection contractor <br />shall be submitted to the Fire Prevention Bureau for approval. <br />• Backflow prevention or connections to the public water mains. <br />111. Electrical conduit shall be provided to each fire protection system control valve <br />including all valve(s) at the water connections. The Livermore - Pleasanton Fire <br />Department requires electronic supervision of all valves for automatic sprinkler <br />systems and fire protection systems. <br />112. Fire hydrant spacing shall be at 400 feet. <br />113. Address numbers shall be installed on the front or primary entrance for all <br />buildings. Minimum building address character size shall be 12" high by 1" stroke. <br />For buildings located greater than 50 feet from street frontage, the character size <br />shall be 16" high by 1 ''A" stroke minimum. Where multiple access is provided, <br />address or tenant space numbers shall be provided on each access door and the <br />character size shall be no less than 4" high by % " stroke. In all cases, address <br />numerals shall be of contrasting background and clearly visible in accordance with <br />the Livermore - Pleasanton Fire Department Premises Identification Standards. <br />This may warrant field verification and adjustments based upon topography, <br />landscaping, or other obstructions. <br />114. The following items will be provided prior to any construction above the foundation <br />or slab. NOTE: Periodic inspections will be made for compliance. <br />a. Emergency vehicle access shall be provided to the site, including the area <br />where construction is occurring. If Public Works improvements are part of the <br />project to access the site, an emergency vehicle access plan shall be <br />submitted for review and approval. <br />b. Multi- family residential developments: Projects having more than 100 dwelling <br />units shall be equipped throughout with two separate and approved fire <br />apparatus access roads. <br />c. Emergency vehicle access shall be a minimum of 20 feet in clear width. A <br />clear height free of obstructions (power, cable, telephone lines, tree limbs, <br />etc.) is required. This clearance shall be a minimum of 13 -feet, 6- inches. <br />Inside turning radius of 45 feet and outside turning radius of 55 feet shall be <br />provided. <br />d. The carrying capacity of the access route(s) shall be 69,000 pounds under <br />all weather conditions. <br />e. Designated construction material storage and construction worker parking <br />shall not obstruct the emergency vehicle access route(s). <br />18 of 28 <br />