Laserfiche WebLink
shall incorporate an inside radius of 45 feet and outside radius of 55 feet to facilitate fire <br /> truck turning radius for entry and exit from the site. <br /> SPECIAL CONDITIONS OF APPROVAL <br /> Traffic <br /> 67. The applicant and/or developer shall be required to make all modifications necessary to <br /> the traffic signal at Stoneridge Drive/Project Entrance to provide full signal operation at <br /> the beginning of construction. These improvements and related plan notes shall be <br /> incorporated into the plans submitted to the Building and Safety Division for plan check <br /> and shall be subject to the review and approval of the City Traffic Engineer prior to <br /> building permit issuance. <br /> SPECIAL CONDITIONS OF APPROVAL <br /> Operation Services Department <br /> 68. A CDS or equivalent storm water pollution control unit shall be installed at the transition <br /> point between the private and public storm line. The storm water pollution control unit is <br /> subject to review and approval of the Director of Operation Services prior to the issuance <br /> of any building permits. <br /> 69. Each individual building shall have a minimum of one grease interceptor on the building <br /> sewer lateral sized for all current and future potential sewer demand. This detail shall be <br /> shown on all building permits and/or tenant improvement permits to the satisfaction of <br /> the City Engineer. <br /> 70. The project applicant/developer shall submit a plan in conformance to the following <br /> water metering requirements: <br /> a) Any single use projected to exceed 5,000 gallons per day requires a dedicated <br /> water meter. <br /> b) Each physically separate building requires a dedicated water meter. <br /> c) Any combination of attached or conjoined buildings or suites in excess of 10,000 <br /> square feet requires a dedicated water meter. <br /> 71. The project applicant/developer shall submit a plan in conformance to the following <br /> backflow protection requirements: <br /> a) All connections to existing 12" water main shall have appropriately sized and type <br /> of Backflow Prevention Device installed to separate the public and privately owned <br /> main. <br /> b) All backflow devices to be located at meters above grade shall be designed per city <br /> standard drawing #706. No backflow devices are allowed in boxes below grade. <br /> c) All fireline Double Check Detector Assemblies shall be located above grade behind <br /> the City sidewalk. <br /> SPECIAL CONDITIONS OF APPROVAL <br /> Engineering <br /> 72. On-site fire hydrants shall be painted Kelly Moore Kel Guard Rust Inhibitive Series per <br /> City of Pleasanton Standard Specification Section 14-02E Fire Hydrants. <br /> 22 <br />