Laserfiche WebLink
EXHIBIT A <br /> the proper length or conform to the seaming diagram as submitted prior to the <br /> installation, shall be rejected from the site. No fitted pieces will be allowed to true <br /> alignment. <br /> 2.07 PERFORMANCE AND TEST REQUIREMENTS <br /> A. Melting Point ASTM 135 degrees C. <br /> D789 <br /> B. Specific Gravity ASTM .950 to .960 <br /> D792 <br /> C Breaking Strength ASTM Length 283 lbs./ft. <br /> D5034 Width 208 lbs. /ft. <br /> D Coefficient of Friction ASTM Dry 1.15 Wet 1.00 <br /> D5034 <br /> E. Pill Burn Test ASTM 8 Passed/0 Failed <br /> D2859 <br /> F. Tuft Bind (without in-fill) ASTM 8 lbs./sq.ft. <br /> Tuft Bind (with in-fill) D1335 <br /> 22 lbs./sq.ft. <br /> ASTM <br /> D1335 <br /> G Pile Height ASTM 1-3/4" minimum <br /> D418 <br /> H Fiber Face Weight ASTM 75 oz./sq. yard total <br /> D418 <br /> I. Fiber Construction ASTM Fibers shall be a combination <br /> D418 of 55oz. of parallel slit film <br /> (1.5mm pattern) having a <br /> denier of 100 micron <br /> (before the oven) with 20 <br /> oz. of nylon (500 denier) <br /> monofilament as a thatch <br /> zone. Total fiber weight <br /> shall be not less than 75 <br /> ounces per square yard. <br /> Gauge Width ASTM Not more than 1/4" max. <br /> D418 <br />