Laserfiche WebLink
Based on the information received, there may be additional requirements such <br /> as: smoke and heat venting, in-rack sprinklers, increases in sprinkler design <br /> criteria, draft curtains, etc. <br /> 95.Electrical conduit shall be provided to each fire protection system control <br /> valve including all valve(s) at the water connections. The Livermore- <br /> Pleasanton Fire Department requires electronic supervision of all valves for <br /> automatic sprinkler systems and fire protection systems. <br /> 96.AII fire sprinkler system water flow and control valves shall be complete and <br /> serviceable prior to final inspection. Prior to the occupancy of a building <br /> having a fire alarm system, the Fire Department shall test and witness the <br /> operation of the fire alarm system. <br /> 97.All commercial, industrial, and multi-family residential occupancies shall have <br /> valve tamper and water flow connected to an Underwriters Laboratory (UL) <br /> listed Central Station Service. Fire Department plan check includes <br /> specifications, monitoring certificate(s), installation certificate and alarm <br /> company UL certificate. Fire alarm control panel and remote annunciation <br /> shall be at location(s) approved by the Fire Prevention Bureau. All systems <br /> shall be point identified by individual device and annunciated by device type <br /> and point. <br /> 98.Electrical conduit shall be provided to each fire protection system control <br /> valve including all valve(s) at the water connections. The Livermore- <br /> Pleasanton Fire Department requires electronic supervision of all valves for <br /> automatic sprinkler systems and fire protection systems. <br /> 99.The following items will be provided prior to any construction above the <br /> foundation or slab. NOTE: Periodic inspections will be made for compliance. <br /> a. Emergency vehicle access shall be provided to the site. If Public Works <br /> Improvements are part of the project to access the site, an emergency vehicle <br /> access plan shall be submitted for review and approval. <br /> b. Site access shall be provided prior to any construction above the foundation <br /> or slab. Based on the Site Plan Approval the access shall be installed. <br /> c. Emergency vehicle access shall be a minimum of 20 feet in width. A clear <br /> height free of obstructions (power, cable, telephone lines, tree limbs, etc.) <br /> shall be provided. This clearance shall be a minimum of 13 feet-6 inches. <br /> Inside turning radius of 45 feet and outside turning radius of 55 feet shall be <br /> provided. <br /> PUD-100 Chick-fil-A <br /> Conditions of Approval (Planning Commission) Page 15 <br />