in a joint utility trench unless otherwise specifically approved by the City <br />Engineer. <br />53.Any damage to existing street improvements during construction on the subject <br />property shall be repaired to the satisfaction of the City Engineer at full expense <br />to the project developer. This shall include slurry seal, overlay, or street <br />reconstruction if deemed warranted by the City Engineer. <br />54. This approval does not guarantee the availability of sufficient water and /or sewer <br />capacity to serve the project. <br />55.There shall be no direct roof leaders connected to the street gutter or storm drain <br />system, unless otherwise approved by the City Engineer. <br />56.The project developer and /or the project developer's contractor(s) shall obtain an <br />encroachment permit from the City Engineer prior to moving any construction <br />equipment onto the site. <br />57. Storm drainage swales, gutters, inlets, outfalls, and channels not within the area <br />of a dedicated public street shall be privately maintained by the property owners. <br />58.AII retaining walls along the street shall be placed behind the Public Service <br />Easement (PSE), unless otherwise approved by the City Engineer. <br />59.A detailed grading and drainage plan prepared by a licensed Civil Engineer <br />including all supporting information and design criteria (including but not limited <br />to any peer review comments), storm drain treatment calculations, <br />hydromodification worksheets, etc., shall be submitted as part of the building <br />permit plans. <br />Fire <br />60.Address numbers shall be installed on the front or primary entrance for all <br />buildings. Minimum building address character size shall be 12" high by 1" <br />stroke. If building is located greater than 50 feet from street frontage, character <br />size shall be 16" high by 1 1/2" stroke minimum. In all cases address numerals <br />shall be of contrasting background and clearly visible in accordance with the <br />Livermore- Pleasanton Fire Department Premises Identification Standards. This <br />may warrant field verification and adjustments based upon topography, <br />landscaping or other obstructions. <br />61.The project developer shall keep the site free of fire hazards from the start of <br />lumber construction until the final inspection. <br />62. Prior to any construction framing, the project developer shall provide adequate <br />fire protection facilities, including, but not limited to a water supply and water flow <br />PUD -102 3192 Santa Rita Road <br />Conditions of Approval Page 9 <br />