171. Automatic fire sprinklers shall be installed in all occupancies in accordance with <br />City of Pleasanton Ordinance 2015. Installations shall conform to NFPA <br />Pamphlet 13 for commercial occupancies. <br />172. Fire alarm system shall be provided and installed in accordance with the CFC <br />currently in effect, the City of Pleasanton Ordinance 2015 and 2010 NFPA 72 - <br />National Fire Alarm Code. Notification appliances and manual fire alarm boxes <br />shall be provided in all areas consistent with the definition of a notification zone <br />(notification zones coincide with the smoke and fire zones of a building). Shop <br />drawings shall be submitted for permit issuance in compliance with the CFC <br />currently in effect. <br />173. City of Pleasanton Ordinance 2015 requires that all new and existing <br />occupancies be provided with an approved key box from the Knox Company as <br />specified by the Fire Department. The applicant is responsible for obtaining <br />approval for location and the number of boxes from the Fire Prevention Bureau. <br />Information and application for Knox is available through their website or the Fire <br />Prevention Bureau. Occupant shall be responsible for providing tenant space <br />building access keys for insertion into the Knox Box prior to final inspection by <br />the Fire Department. Keys shall have permanent marked tags identifying <br />address and /or specific doors /areas accessible with said key. <br />174. Underground fire mains, fire hydrants and control valves shall be installed in <br />conformance with the most recently adopted edition of NFPA Pamphlet 24, <br />"Outside Protection ". <br />• The underground pipeline contractor shall submit a minimum of three (3) sets <br />of installation drawings to the Fire Department, Fire Prevention Bureau. The <br />plans shall have the contractor's wet stamp indicating the California contractor <br />license type, license number and must be signed. No underground pipeline <br />inspections will be conducted prior to issuance of approved plans. <br />• All underground fire protection work shall require a California contractor's <br />license type as follows: C -16, C -34, C -36 or A. <br />• All field- testing and inspection of piping joints shall be conducted prior to <br />covering of any pipeline. <br />175. Portable fire extinguisher(s) shall be provided and installed in accordance with <br />the California Fire Code currently in effect and Fire Code Standard #10 -1. <br />Minimum approved size for all portable fire extinguishers shall be 2A 10B:C. <br />Building <br />176. The project developer shall submit a building survey and /or record of survey and <br />a site development plan in accordance with the provisions of Chapter 18.68 of <br />the Municipal Code of the City of Pleasanton. These plans shall be approved by <br />the Chief Building and Safety Official prior to the issuance of a building permit. <br />PUD -106, Chrylser- Jeep -Dodge Page 32 <br />
The URL can be used to link to this page
Your browser does not support the video tag.