to commencing operations. Please contact the hazardous materials staff at <br />925/454 -2332. <br />157. The Fire Prevention Bureau reviews building /civil drawings for conceptual on -site <br />fire mains and fire hydrant locations only. Plan check comments and approvals <br />DO NOT INCLUDE: <br />a. Installation of the on -site fire mains and fire hydrants. Specific installation <br />drawings submitted by the licensed underground fire protection contractor <br />shall be submitted to the Fire Prevention Bureau for approval. <br />b. Backflow prevention or connections to the public water mains. <br />158. Emergency vehicle access roads: <br />• Shall be a minimum of 20 feet in width. A clear height free of obstructions <br />(power, cable, telephone lines, tree limbs, etc.) shall be provided. This <br />clearance shall be a minimum of 13 feet -6 inches. Inside tuming radius of <br />41 feet and outside turning radius of 52 feet shall be provided. <br />• All exterior portions of buildings must be within 200 feet of an access road. <br />Yard and parking areas may be able to be located farther than 200 feet <br />from access roads, depending on the specific use. <br />• On -site access ways and internal drives shall be designated as fire lanes <br />and identified as such by red curb striping and posted with signs at <br />locations approved by the Fire Department. Signs shall be according to <br />state standards and read "No Parking - Fire Lane" and must be shown on <br />the plans. <br />159. Fire department aerial apparatus: <br />• Buildings or portions of buildings or facilities exceeding 30 feet (9144 mm) <br />in height above the lowest level of fire department vehicle access shall be <br />provided with approved fire apparatus access roads capable of <br />accommodating fire department aerial apparatus. Fire apparatus access <br />roads shall have a minimum unobstructed width of 26 feet in the <br />immediate vicinity of any building or portion of building more than 30 feet <br />(9144 mm) in height. At least one of the required access routes meeting <br />this condition shall be located within a minimum of 15 feet (4572 mm) and <br />a maximum of 30 feet (9144 mm) from the building, and shall be <br />positioned parallel to one entire side of the building. <br />• The following schedule for NO PARKING signs shall apply: <br />Width Requirements <br />36 Feet or Greater No Requirements <br />Between 28 and 36 Feet Post one side <br />Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />Aerial Ops - Width Requirements <br />42 Feet or Greater No Requirements <br />Between 34 and 42 Feet Post one side <br />PUD -106, Chrylser- Jeep -Dodge Page 29 <br />