Laserfiche WebLink
20.10.090 CRC Section R329 added - Installation of Spark Arrestors <br /> Chapter 3 is amended by adding Section R329 Installation of Spark Arrestors to read as <br /> follows: <br /> R329 Installation of Spark Arrestors. Existing one- and two-family dwellings shall be <br /> retrofitted with a spark arrestor upon the occurrence of any of the following events: <br /> 1. Upon notice from the City; <br /> 2. Re-roofing; <br /> 3. Resale of the dwelling unit; <br /> 4. Issuance of a building permit for alterations, repairs or additions in excess of <br /> $1,000. <br /> In the event of a resale of a dwelling unit, the seller shall be responsible to comply with <br /> this ordinance. Any real property professional representing the seller shall be required <br /> to notify the seller of seller's obligation to comply with this ordinance. <br /> The spark arrestor shall conform to the requirements specified in the CRC Section <br /> R1003.9.1. <br /> 20.10.100 CRC Section R403.1.3 amended — Seismic Reinforcing. <br /> Section R403.1.3 is amended to read as follows: <br /> R403.1.3 Seismic reinforcing. Concrete footings located in Seismic Design Categories <br /> Do, D1 and D2, as established in Table R301.2(1), shall have minimum reinforcement of <br /> at least two continuous longitudinal reinforcing bars not smaller than No. 4 bars. Bottom <br /> reinforcement shall be located a minimum of 3 inches (76 mm) clear from the bottom of <br /> the footing. <br /> In Seismic Design Categories Do, D1 and D2 where a construction joint is created <br /> between a concrete footing and a stem wall, a minimum of one No. 4 bar shall be <br /> installed at not more than 4 feet (1219 mm) on center. The vertical bar shall extend to 3 <br /> inches (76 mm) clear of the bottom of the footing, have a standard hook and extend a <br /> minimum of 14 inches (357 mm) into the stem wall. <br /> In Seismic Design Categories Do, D1 and D2 where a grouted masonry stem wall is <br /> supported on a concrete footing and stem wall, a minimum of one No. 4 bar shall be <br /> installed at not more than 4 feet (1219 mm) on center. The vertical bar shall extend to 3 <br /> inches (76 mm) clear of the bottom of the footing and have a standard hook. <br /> In Seismic Design Categories Do, D1 and D2, masonry stem walls without solid grout <br /> and vertical reinforcing are not permitted. <br /> Exception: In detached one- and two-family dwellings which are three stories or less <br /> in height and constructed with stud bearing walls, isolated plain concrete footings <br /> supporting columns or pedestals are permitted. <br /> 20.10.110 CRC Section R507.1 amended — Decks <br /> Section R507.1 is amended to read as follows: <br />