Laserfiche WebLink
137. Fire alarm system shall be provided and installed in accordance with the CFC <br /> currently in effect, the City of Pleasanton Ordinance 2015 and 2002 NFPA 72 - <br /> National Fire Alarm Code. Notification appliances and manual fire alarm boxes <br /> shall be provided in all areas consistent with the definition of a notification zone <br /> (notification zones coincide with the smoke and fire zones of a building). Shop <br /> drawings shall be submitted for permit issuance in compliance with the CFC <br /> currently in effect. <br /> 138. Underground fire mains, fire hydrants and control valves shall be installed in <br /> conformance with the most recently adopted edition of NFPA Pamphlet 24, <br /> "Outside Protection." <br /> a. The underground pipeline contractor shall submit a minimum of three (3) sets <br /> of installation drawings to the Fire Department, Fire Prevention Bureau. The <br /> plans shall have the contractor's wet stamp indicating the Caliornia contractor <br /> license type, license number and must be signed. No underground pipeline <br /> inspections will be conducted prior to issuance of approved plans. <br /> b. All underground fire protection work shall require a California contractor's <br /> license type as follows: C-16, C-34, C-36 or A. <br /> c. All field-testing and inspection of piping joints shall be conducted prior to <br /> covering of any pipeline. <br /> 139. Dead-end fire service water mains shall not exceed 500 feet in length and/or <br /> have more than five Fire Department appliances* shall be loopec around the site <br /> or building and have a minimum of two points of water supply or street <br /> connection. Zone valves shall be installed as recommended under NFPA, <br /> Pamphlet 24 and the Fire Marshal. <br /> *Note: Fire Department appliances are classified as fire sprinkler system risers, <br /> fire hydrants and/or standpipes. <br /> 140. Portable fire extinguisher(s) shall be provided and installed in accordance with <br /> the California Fire Code currently in effect and Fire Code Standard #10-1. <br /> Minimum approved size for all portable fire extinguishers shall be 2A 10B:C. <br /> 141. All buildings undergoing construction, alteration or demolition shall comply with <br /> Chapter 14 (California Fire Code currently in effect) pertaining to the use of any <br /> hazardous materials, flame- producing devices, asphalt/tar kettles, etc. <br /> 142. The building (s) covered by this approval shall conform to the requirements of the <br /> California Building Code currently in effect, the California Fire Code currently in <br /> effect and the City of Pleasanton Ordinance 2015. If required plans and <br /> specifications for the automatic fire sprinkler system shall be submitted to the <br /> 14-Unit Development Plan Ponderosa Homes <br /> PUD-97, Conditions of Approval 24 of 31 4202 Stanley Boulevard <br />