20.24.250 CFC Section 2703.2.2.1 Item 7 added — Secondary containment. <br /> Section 2703.2.2.1 Item 7 is added to read: <br /> 7. Secondary containment or equivalent protection from spills shall be provided for <br /> piping for liquid hazardous materials where a spill is determined to be a plausible <br /> event and where such an event would endanger people, property or the <br /> environment and for highly toxic, toxic, and corrosive gases above threshold <br /> quantities listed in Tables 3704.2 and 3704.3. Secondary containment includes, <br /> but is not limited to double walled piping. <br /> Exceptions: <br /> 1. Secondary containment is not required for corrosive gases if the piping is <br /> constructed of inert materials. <br /> 2. Piping under sub- atmospheric conditions if the piping is equipped with an <br /> alarm and fail -- safe -to -close valve activated by a loss of vacuum. <br /> 20.24.260 CFC Section 2703.2.2.1 Item 8 added — Low melt point materials. <br /> Section 2703.2.2.1 Item 8 is added to read: <br /> 8. <br /> ow melt point materials, such as plastic, shall not be used for oxidizing materials, <br /> flammable materials, combustible liquids, pyrophoric materials, toxic gases, <br /> highly toxic gases, or moderately toxic gases. <br /> Exception: Facility specific systems approved by the Fire Chief. <br /> 20.24.270 CFC Section 2703.2.2.2 amended — Additional regulations for supply <br /> piping for health hazard materials. <br /> Section 2703.2.2.2 is amended to read: <br /> 2703.2.2.2 Additional regulations for supply piping for health hazard materials. <br /> Supply piping and tubing for gases and liquids having a health hazard ranking of 3 or 4 <br /> in accordance with NFPA 704 shall be in accordance with ASME B31.3 and the <br /> following: <br /> 1. Piping and tubing utilized for the transmission of toxic, highly toxic, moderately <br /> toxic gases or highly volatile corrosive liquids and gases shall have welded, or <br /> brazed connections throughout except for connections within an exhausted <br /> enclosure if the material is a gas, or an approved method of drainage or <br /> containment is provided for connections if the material is a liquid. <br /> 63 <br />
The URL can be used to link to this page
Your browser does not support the video tag.