Laserfiche WebLink
STONERIDGE DRIVE SPECIFIC PLAN AMENDMENT /STAPLES RANCH PROJECT <br /> MITIGATION MONITORING AND REPORTING PLAN [May 2010] <br /> Date Completed/ <br /> Mitigation Measures/Improvement Measures Monitoring Action Responsibility'' Timing Signature <br /> NO -1.5 Limit noise levels from auto mall car wash stations to 60 dBA at Verify that noise levels Verification: City of Prior to issuance <br /> the senior continuing care community facility. At the auto mall, an car from auto mall car wash Pleasanton Planning of a Building Signature <br /> station do not exceed 60 Division. Permit. <br /> washes shall be located and designed such that noise from the car washes, dBA at the senior Title <br /> including the vacuuming areas, shall not exceed 60 dBA at any habitable continuing care Implementation: <br /> structure. The project developer shall submit a noise study to the community facility; Project Developer for Date <br /> Community Development Director verifying that the carwashes adhere to field inspections. the auto mall. <br /> this requirement, prior to the issuance of a building permit. Field inspections Field inspections: <br /> during construction: Prior to <br /> City of Pleasanton occupancy. <br /> Building and Safety <br /> Division. <br /> NO -2.1 Reduce potential pile driving vibration effects on nearby Verify that a site- Verification: City of Prior to pile <br /> structures below the structural damage threshold. To mitigate potential specific engineering Pleasanton driving activities. Signature <br /> assessment is completed Engineering Division. <br /> pile driving vibration impacts, a site specific engineering assessment shall and reviewed by the Title <br /> be completed under the supervision of a qualified vibration consultant to City Engineer; pile Implementation: <br /> assure that there would be no potential for structural damage to nearby driving is supervised by Project Sponsor; for Date <br /> existing buildings, based on a vibration damage threshold for a peak a qualified vibration potential <br /> particle velocity (PPV) of 0.20 inches per second. This plan shall be consultant; field pedestrian /bike bridge, <br /> inspections. City of Pleasanton. <br /> submitted for review and approval by the City Engineer prior to final <br /> approval of the bridge plans to ensure that maximum feasible vibration Endnote #5 applies. <br /> reduction is achieved. These reduction measures could include pile <br /> driving techniques that have a lower potential for vibration impacts such Field inspections Field inspections: <br /> during construction: Prior to <br /> as vibratory pile driving, pre drilled pile holes, etc. as recommended by City of Pleasanton occupancy. <br /> the consultant. The effectiveness of the vibration control measures shall Building and Safety <br /> be verified by vibration monitoring measurements during bridge pile- Division. <br /> driving activities. <br /> NO -2.2 Provide early notices. Prior to final approval of the Stoneridge Verify that early notice Verification: City of Prior to final <br /> Drive bridge plans, a list of measures to respond to and track complaints procedures are Pleasanton approval of the Signature <br /> conducted. Engineering Division. Stoneridge Drive <br /> pertaining to bridge construction vibration shall be submitted to the City bridge plans. Title <br /> 28 <br />