My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(B) Disconnection of Conductors. The ungrounded con- <br />ductors of the faulted source circuit shall be automatically <br />disconnected. If the grounded conductors of the faulted <br />source circuit are disconnected to comply with the require- <br />ments of 690.5(A), all conductors of the faulted source <br />circuit shall be opened automatically and simultaneously. <br />Opening the grounded conductor of the array or opening <br />the faulted sections of the array shall be permitted to inter- <br />rapt the ground-fault current path. <br /> <br />(C) Labels and Markings. Labels and markings shall be <br />applied near the ground-fault indicator at a visible location, <br />stating that, if a ground fault is indicated, the normally <br />grounded conductors may be energized and ungrounded. <br /> <br />690.6 Alternating-Current Modules. <br /> <br />(A) Photovoltaic Source Circuits. The requirements of <br />Article 690 pertaining to photovoltaic source circuits shall <br />not apply to ac modules. The photovoltaic source circuit, <br />conductors, and inverters shall be considered as internal <br />wiring of an ac module. <br /> <br />(B) Inverter Output Circuit. The output of an ac module <br />shall be considered an inverter output circuit. <br /> <br />(C) Disconnecting Means. A single disconnecting means, in <br />accordance with 690.15 and 690.17, shall be permitted for <br />the combined ac output of one or more ac modules. <br />Additionally, each ac module in a multiple ac-module sys- <br />tem shall be provided with a connector, bolted, or terminal <br />type disconnecting means. <br /> <br />(D) Ground-Fault Detection. Alternating-current-module <br />systems shall be permitted to use a single detection device <br />to detect only ac ground faults and to disable the array by <br />removing ac power to the ac module(s). <br /> <br />(E) Over current Protection. The output circuits of ac <br />modules shall be permitted to have over current protection <br />and conductor sizing in accordance with 240.5(B)(2). <br /> <br />II. Circuit Requirements <br /> <br />67 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.