My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
690.7 Maximum Voltage. <br /> <br />(A) Maximum Photovoltaic System Voltage. In a do pho- <br />tovoltaic source circuit or output circuit, the maximum pho- <br />tovoltaic system voltage for that circuit shall be computed <br />as the sum of the rated open-circuit voltage of the series <br />connected photovoltaic modules corrected for the lowest <br />expected ambient temperature. For crystalline and multi- <br />crystalline silicon modules, the rated open-circuit voltage <br />shall be multiplied by the correction factor provided in <br />Table 690.7. This voltage shall be used to determine the <br />voltage rating of cables, disconnects, over current devices, <br />and other equipment. Where the lowest expected ambient <br />temperature is below -40°C (-40°F), or where other than <br />crystalline or multi-crystalline silicon photovoltaic modules <br />are used, the system voltage adjustment shall be made in <br />accordance with the manufacturer's instructions. <br /> <br />Table 690.7 Voltage Correction Factors for Crystalline and Multi- <br /> crystalline Silicon Modules <br /> <br /> Correction Factors for <br /> Ambient Temperatures <br /> Below 25°C (77°F) <br /> (Multiply the rated <br /> open-circuit voltage by <br /> the appropriate <br />Ambient correction factor shown Ambient <br />Temperature below.) Temperature <br />(°C) (°F) <br /> <br /> 25 to 10 1.06 77 to 50 <br /> 9to0 1.10 49to32 <br /> -1 to-10 1.13 31 to 14 <br /> -11 to -20 1.17 13 to -4 <br /> -21 to -40 1.25 -5 to -40 <br /> <br />(B) Direct-Current Utilization Circuits. The voltage of do <br />utilization circuits shall conform with 210.6. <br /> <br />(C) Photovoltaic Source and Output Circuits. In one and <br />two-family dwellings, photovoltaic source circuits and <br />photovoltaic output circuits that do not include lamphold- <br />ers, fixtures, or receptacles shall be permitted to have a <br />maximum system voltage up to 600 volts. Other installa- <br /> <br />68 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.