My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.08.044 Section 1701.5 Item 5.2 Amended - Special Moment-Resisting <br /> Steel Frames <br /> <br />Section 1701.5 item 5.2 of the California Building Standards Code 2001 <br /> edition (24 CCR), and including by reference the uniform building <br /> code, 1997 edition, is amended to read as follows: <br /> <br />5.2 Special momem-resisting steel. In Seismic Zones 3 and <br />4, and in buildings in Seismic Zone No. 2 with an <br />importance factor I greater than 1.0, welded joints in <br />Special, Ordinary and Special Truss Moment Frames; in <br />Special and Ordinary Concentrically Braced Frames, and in <br />Eccentrically Braced Frames that are part of the Lateral <br />Force Resisting System shall be inspected in accordance <br />with AISC Seismic Part I Section 16. In addition to Item <br />5.1 requirements, nondestructive testing shall be as required <br />by Section 1703 of this code. <br /> <br />Section 20.08.045 Section 904.1.2 Amended Standards Fire <br /> <br />Extinguishing Systems: <br /> <br />Section 904.1.2 of the Califomia Building Standards Code, 2001 Edition <br /> (24 CCR), and including by reference the Uniform Building Code, <br /> 1997 Edition, is amended to mad as follows: <br /> <br />Standards. Fire-extinguishing systems shall comply with <br />City of Pleasanton Sprinkler Standard 9-3 (NFPA 13D <br />1999 Edition) for one to fifteen family dwelling units (not <br />exceeding 12,000 sf in any one building), and UBC <br />Standard 9-1 for all other occupancies. <br /> <br />20.08.046 Section 1703 First Paragraph Only Amended - Nondestructive <br /> Testing: <br /> <br />Section 1703 of the Califomia Building Standards Code 2001 Edition (24 <br /> CCR), and including by reference the Uniform Building Code, 1997 <br /> edition, is amended to read as follows: <br /> <br />1703. In Seismic Zones 3 and 4, and in buildings in <br />Seismic Zone No. 2 with an importance factor I greater <br />than 1.0, all complete-joint-penetration groove and partial- <br />joint-penetration groove welded joints in Special, Ordinary <br />and Special Truss Moment Frames; in Special and Ordinary <br />Concentrically Braced Frames, and in Eccentrically Braced <br />23 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.