My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. All braced wall panels shall be clearly indicated on the <br />plans. <br />4. Construction of braced wall panels shall be by one of the <br />following methods: <br />4.1 Wood boards of 5/8 inch (16 mm) net minimum <br />thickness applied diagonally on studs spaced not over 24 <br />inches (610 mm) on center. <br />4.2 Wood structural panel sheathing with a thickness not <br />less than 5/16 inch (7.9 mm) for 16 inch (406 mm) stud <br />spacing and not less than 3/8 inch (9.5 mm) for 24 inch <br />(610 mm) stud spacing in accordance with Tables 23-II-A-1 <br />and 23-IV-D- 1. <br />4.3 Fiberboard sheathing 4 foot by 8 foot (1219 rmn by <br />2438 mm) panels not less than 1/2 inch (13 mm) thick <br />applied vertically on studs spaced not over 16 inches (406 <br />mm) on center when installed in accordance with Section <br />2315.6 and Table 23-II-J. <br />4.4 Particleboard wall sheathing panels where installed in <br />accordance with Table 23-IV-D-2. <br /> <br />20.08.038 Section 1629.4.2 amended - Seismic Zone 4 near-source factor <br /> <br />Section 1629.4.2 of the California Building Standards Code 2001 Edition <br /> (24 C.C.R.), and including by reference the Uniform Building <br /> Code, is amended to read as follows: <br /> <br />1629.4.2. Seismic Zone 4 near-source factor. In Seismic <br />Zone 4, each site shall be assigned a near-source factor in <br />accordance with Table 16-S and the Seismic Source Type <br />set forth in Table 16-U. The value of Na used in <br />determining Ca need not exceed 1.1 for structures <br />complying with all the following conditions: <br /> <br />18 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.