c. Sliver fill shall not be used to create graded lots. <br /> <br /> d. The maximum grade at street intersections except Bernal <br /> Avenue shall be 7%. <br /> <br /> e. Grading of lots 24 through 28 shall be designed to pass <br /> surface runoff from adjacent property to "G" Court. <br /> <br />14. Engineering Requirements <br /> <br /> a. Any two-story house with a pad elevation greater than <br /> 540' or single-story house with a pad elevation greater <br /> than 550' shall be provided with a domestic booster pump <br /> which will maintain a minimum operating water pressure of <br /> 40 psi. Individual lot booster pumps shall be installed <br /> as necessary bythe developer on all but the custom lots. <br /> Custom lot owners shall provide their own, as necessary. <br /> The developer shall disclose to all prospective buyers of <br /> the custom and split pad lots with a pad grade greater <br /> than elevation 540' that the water pressure delivered to <br /> the lot on an average day may be less than 40 psi. for <br /> these lots. This notice shall be reviewed and approved <br /> by the City Attorney prior to the sale of any unit in <br /> this project. This notice shall be included in all deeds <br /> to affected individual properties. <br /> <br /> b. The developer shall dedicate to the City a 20' strip of <br /> land next to the existing lot at the top of Abbie Street <br /> (north side), the length of which shall be the same as <br /> that existing lot's depth. The developer shall construct <br /> a 12' wide paved road within this parcel for public <br /> access to the existing sewer main. Lots 113C and 108 <br /> shall be reconfigured as necessary to accommodate this <br /> access way. <br /> <br /> c. The developer shall pay a pro-rata share, as determined <br /> by the City Engineer of the installation of an 8" <br /> sanitary sewer in Bernal Avenue between Windmill Way and <br /> Puerto Vallerta, approximately 450'. <br /> <br /> d. The developer shall pay a pro-rata share, as determined <br /> by the City Engineer of the installation of a 10" water <br /> line in Bernal Avenue between Independence Drive and <br /> Windmill Way, approximately 500'. <br /> <br /> c. All sanitary sewers and laterals shall be designed to <br /> flow by gravity, unless otherwise approved by the City <br /> Engineer. <br /> <br /> d. The storm drain for the Mirador Drive extension shall be <br /> designed such that the natural swale located on lot 49C <br /> receives only a small amount of water during the time of <br /> <br /> - 17 - <br /> <br /> <br />