My WebLink
|
Help
|
About
|
Sign Out
ORD 1669
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1601 - 1700
>
ORD 1669
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2004 12:09:46 PM
Creation date
3/9/1999 7:37:04 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT NO
ORD 1669
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ordinance No. 1669 <br />Page 9 <br /> <br /> section to remain.) <br /> <br /> 20.08.053 Section 1806.1 amended - Footinqs and <br /> Foundations, General <br /> <br /> Section 1806.1 of the Uniform Building Code is <br /> amended to read as follows: <br /> <br /> General. Footings and foundations shall be <br /> constructed of masonry, concrete or treated <br /> wood in conformance with Division II and shall <br /> extend below the frost line. Footings of <br /> concrete and masonry shall be of solid <br /> material. Foundations supporting wood shall <br /> extend at least 6 inches (152mm) above the <br /> adjacent finish grade. Footings shall have a <br /> minimum depth as indicated in Table 18-I-D <br /> unless another depth is recommended by a <br /> foundation investigation. A minimum of one top <br /> and one bottom continuous bars of 1/2" <br /> diameter reinforcing steel shall be required <br /> in all continuous concrete or masonry bearing <br /> foundations. <br /> <br /> 20.08.055 Section 1924 amended - Minimum Slab <br /> Thickness. <br /> <br /> Section 1924 of the Uniform Building Code is <br /> amended to read as follows: <br /> <br /> Minimum slab thickness. The minimum thickness <br /> of concrete floor slabs supported directly on <br /> the ground shall not be less than 3 1/2 inches <br /> (89mm). The slab shall be reinforced with not <br /> less than six inches by six inches ten gauge <br /> welded wire mesh or an approved alternate <br /> installed at mid height of the slab. <br /> <br /> 20.08.057 Section 2326.11.3 amended - Portland <br /> cement plaster on studs. <br /> <br /> Section 2326.11.3, Item 7, of the Uniform <br /> Building Code is amended to read as follows: <br /> <br /> Portland cement plaster on studs spaced 16 <br /> inches on center installed in accordance with <br /> Table No. 47-I. (Limited to single story Group <br /> R-3 and M-1 occupancies). <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.