My WebLink
|
Help
|
About
|
Sign Out
ORD 1610
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1601 - 1700
>
ORD 1610
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2003 12:40:42 PM
Creation date
3/9/1999 6:08:29 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT NO
ORD 1610
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a. The applicant fails to receive growth management <br /> approval within 2½ years of PUD approval, or <br /> <br /> b. Subsequent to such approval, the applicant allows ~he <br /> growth management approval to lapse. <br /> <br /> If growth management lapses on a project phase, then the <br /> portions of the development plan without final map approval <br /> shall expire with no further force or effect. <br /> <br />15. All dwelling units in the development shall be constructed <br /> to meet Title 24 state energy requirements. <br /> <br />16. The developer shall submit a building survey and/or a record <br /> of survey and a site development plan in accordance with the <br /> provisions of Chapter 18.68 of the Municipal Code of the <br /> City of Pleasanton, and these plans must be approved by the <br /> Director of Building Inspection prior to the issuance of a <br /> building permit. The site development plan shall include <br /> all required information to design and construct the site, <br /> grading, paving, drainage and utilities. Specific items to <br /> be indicated on the site development plan necessary to <br /> construct the improvements are to be in accordance with the <br /> City of Pleasanton Private Development Design Guidelines <br /> adopted April 15, 1986. <br /> <br />17. This project shall be subject to all fees, codes, and other <br /> regulations in effect at the time the various approvals <br /> and/or permits are granted (final maps, building permits, <br /> etc.). <br /> <br />18. The paving sections for the on-site parking and drive areas <br /> shall be designed on the basis of an R-Value test and a <br /> traffic index to carry the anticipated traffic loads. This <br /> design shall be subject to the approval of the Director of <br /> Building Inspection. The minimum paving section shall be 2" <br /> A.C. on 6" of A.B. or as recommended by a registered soils <br /> engineer, whichever is greater. The minimum A.C. pavement <br /> slope shall be 1%. For pavement slopes of less than 1%, the <br /> surface runoff ~hall be carried in a concrete gutter to an <br /> acceptable point of discharge. The minimum slope for <br /> concrete gutters shall be 0.5%. <br /> <br />19. Fire Department Requirements: <br /> <br /> a. The applicant shall post address numerals on the <br /> building so as to be plainly visible from all adjcining <br /> streets or driveways during both daylight and night <br /> time hours. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.