My WebLink
|
Help
|
About
|
Sign Out
ORD 1721
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1701 - 1800
>
ORD 1721
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:23 PM
Creation date
3/8/1999 7:04:46 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT NO
ORD 1721
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
plan check set whether underground cable will be available on-site and shall indicate the <br /> potential location of any future satellite dish. <br /> <br /> 34. The applicants shall instail a lighted directory showing the location of building clusters, <br /> units, and streets, near the secondary driveways on Owens and Hacienda Drives. In <br /> addition, the applicants shall install on- and off-site City park signs per the direction of <br /> the City's Park and Recreation Director. Prior to the issuance of building permits the <br /> developer shall submit to the Planning Director for review and approval the proposed <br /> monument entry sign, complex directory signs, on-site directional signs, and City park <br /> signs. The sign package shall contain details on the size of signs, lettering, placement of <br /> addresses, lighting, materials, construction, and finish colors and materials. The sign <br /> package shall include addresses for all four sides of each building to distinguish it from <br /> others. The building address signs shall be plainly visible from all adjoining streets or <br /> driveways during both daylight and night time hours. Minimum size shall be 6 in. high <br /> by 1 in. stroke. This sign package must be reviewed and approved by the Hacienda <br /> Owners Association prior to submittal to the City. <br /> <br />35. All trash enclosures shall match the materials and colors of the building. The applicants <br /> shall include trash enclosure elevations on the plans submitted for issuance of building <br /> permits. Said plans shall be subject to review and approval by the Planning Director <br /> prior to issuance of building permits. Trash containers shall be stored within the <br /> enclosures at all times, except when being unloaded. <br /> <br />36. Except as modified by condition no. 26, the applicants shall effectively screen from view <br /> all ducts, meters, air conditioning equipment, and any other mechanical equipment, <br /> whether on the structure, on the ground, or on the roof, with materials architecturally <br /> compatible with the main structure. Screening details shall be shown on the plans <br /> submitted for issuance of building permits, the adequacy of which shall be determined by <br /> the Planning Director. All required screening shall be provided prior to building <br /> occupancy. <br /> <br />37. All mechanical equipment shall be constructed in such a manner that noise emanating <br /> from it will not be perceptible beyond the property plane of the subject property in a <br /> normal environment for that zoning district. <br /> <br />38. The applicants shall submit a final lighting plan for the building and the site for the <br /> review and approval of the Planning Director prior to issuance of building permits. Light <br /> standards in the parking lot areas shall not exceed 12 ft. tall and, if determined necessary <br /> by the Planning Director, shall incorporate cut-off shield type fixtures to prevent glare <br /> onto adjacent properties or roadways. <br /> <br />39. All parking spaces shall be striped. Wheel stops shall be provided unless the spaces are <br /> fronted by concrete curbs, in which case sufficient areas shall be provided beyond the <br /> ends of all parking spaces to accommodate the overhang of automobiles. <br /> <br />Conditions of Approval PUD-81-30-71D <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.